Yes, it it surprising to me as well.
For me they sometimes work, sometimes not. I was able to figure out why this is,...
For me they sometimes work, sometimes not. I was able to figure out why this was,...
The data register wait timing is unfortunately much harder to pin down, it varies...
I noted a discrepancy between the timing of the CALL instruction, in my measurements...
I’ve performed cycle-accurate R800 timing tests on my turboR GT, see the R800+wait...
Regarding the discrepancy between the PCM wait (85.16 clocks vs. 88 clocks in the...
After a test with cycle-accurate timing on turboR, I have established that: The required...