#81 Wrong CRC-16 (Modbus) for specific input data

V3.0.0.30
closed-fixed
nobody
None
V3.0.0.26
5
2017-05-08
2017-04-27
p.h.
No
  1. Open Send tab.
  2. Enter string $10 $30 $03 0 0 0 0 222 0 2 2 into box.
  3. Check +CRC and select CRC-16 (Modbus)
  4. Click Numbers
  5. Notice added CRC-16 (Modbus) differs from correct 0xFC 0xA2.
  6. Enter string $10 $30 $03 0 0 0 0 221 0 2 2 into box.
  7. Repeat steps 2-6.
  8. Notice this time added CRC is fine.

I hope this helps.

Discussion

  • Simon Bridger

    Simon Bridger - 2017-04-28
    • status: open --> closed-fixed
    • Fixed_in_Version: Not Fixed --> V3.0.0.26
     
  • Simon Bridger

    Simon Bridger - 2017-04-28

    Use current development version www.i2cchip.com/realterm
    See changelog, fixed 3.0.0.24 12May15

    works OK 3.0.0.32

     
  • p.h.

    p.h. - 2017-05-08

    Where to find 3.0.0.32? I see the newest beta to download is still 3.0.0.31 from March and the bug affects it (checked).

     