User Activity

  • Posted a comment on discussion General Discussion on jkaptive

    I haven't used it much since 2015, and the SF.net user interface confuses me a lot. Maybe I should move it to GitHub and revise it?

  • Posted a comment on a wiki page on owfs and owhttpd

    We moved the project to GitHub. Please post your wish for assistance there. https://github.com/owfs/owfs/issues Thank you, Jan

  • Posted a comment on ticket #73 on owfs and owhttpd

    This is an error in the Debian packaging. Please update to Debian Stretch or newer.

  • Committed [93c1f3]

    Release 3.2p2

  • Modified a comment on discussion Help on owfs and owhttpd

    This doesn't depend on the host adapter you use. With the DS2438, OWFS has temperate+voltage→humidity formulas for the Humirel HTM1735 and for the Honeywell HIH3600, HIH4000, and HIH5030. For other "raw" sensors, you can either calculate it yourself or we could add support. You may want to consider the iButtonLink SmartSlave SS-Wall-TH, which is supported by recent OWFS out-of-the-box. Another solution is to use an I²C humiditiy sensor as the HTU21 or AM2315 and connect them to Onewire through an...

  • Modified a comment on discussion Help on owfs and owhttpd

    This doesn't depend on the host adapter you use. With the DS2438, OWFS has temperate+voltage formulas for the Humirel HTM1735 and for the Honeywell HIH3600, HIH4000, and HIH5030. For other "raw" sensors, you can either calculate it yourself or we could add support. You may want to consider the iButtonLink SmartSlave SS-Wall-TH, which is supported by recent OWFS out-of-the-box. Another solution is to use an I²C humiditiy sensor as the HTU21 or AM2315 and connect them to Onewire through an DS28E17...

  • Modified a comment on discussion Help on owfs and owhttpd

    This doesn't depend on the host adapter you use. With the DS2438, OWFS has temperate+voltage formulas for the Humirel HTM1735 and for the Honeywell HIH3600, HIH4000, and HIH5030. For other "raw" sensors, you can either calculate it yourself or we could add support. You may want to consider the iButtonLink SmartSlave SS-Wall-TS, which is supported by recent OWFS out-of-the-box. Another solution is to use an I²C humiditiy sensor as the HTU21 or AM2315 and connect them to Onewire through an DS28E17...

  • Posted a comment on discussion Help on owfs and owhttpd

    This doesn't depend on the host adapter you use. With the DS2438, OWFS has temperate+voltage formulas for the Humirel HTM1735 and for the Honeywell HIH3600, HIH4000, and HIH5030. For other "raw" sensors, you can either calculate it yourself or we could add support. You may want to consider the iButtonLink SmartSlave SS-Wall-TS, which is also supported by OWFS. Another solution is to use an I²C humiditiy sensor as the HTU21 or AM2315 and connect them to Onewire through an DS28E17 Onewire to I²C brigde....