Activity for Scott Criswell

  • Scott Criswell Scott Criswell committed [r2491] on Code

    CBECC-Res 2022/25 (1360) executable fix for bug where 'no gas' rate CSVs causing crash

  • Scott Criswell Scott Criswell committed [r8645] on Code

    latest CSE (0.922.1+perfmap.ec29d428.128) executable which enables larger performance map objects (more data points)

  • Scott Criswell Scott Criswell committed [r2490] on Code

    CBECC-Res 2022/25 (1359) executable and ruleset source update fixes/improvements to CUAC Combine Reports feature (tic #1386)

  • Scott Criswell Scott Criswell committed [r8644] on Code

    CBECC-25 (1359) and OpenStudio update consistent w/ NREL/KB latest commit

  • Scott Criswell Scott Criswell committed [r2489] on Code

    CBECC-Res 2022/25 (1359) executables and ruleset source including first operational version of the CUAC Report Combination feature (tic #1386)

  • Scott Criswell Scott Criswell posted a comment on ticket #1386

    Question - If and how to report certain data that will likely/potentially vary across range of runs/reports being combined, including: Run date/time, Software & Compliance version, Tariff date, Street address, Project ID and Draft/Final/Annual report type? Perhaps write into report "<combined report="">" (or something similar) for some/any of these fields that vary across the runs being combined?</combined>

  • Scott Criswell Scott Criswell modified ticket #1386

    CUAC Reports Combined

  • Scott Criswell Scott Criswell posted a comment on ticket #1386

    Substantial progress - but taking longer than anticipated. UI, defaulting and parsing of Details CSV file complete - more work needed to produce the combined report. Shooting for test version by/before Wed 11/6 and completion in following week.

  • Scott Criswell Scott Criswell committed [r8639] on Code

    Updated OpenStudio (EPlus v9.4) DLL and corresponding CBECC (1358) executables addressing SourceForge tic #3587 - adding a corresponding minimum electric equipment load when gas is not available in the building

  • Scott Criswell Scott Criswell committed [r8638] on Code

    Updated OpenStudio DLL and corresponding CBECC (1358) executables addressing SourceForge tic #3587 - adding a corresponding minimum electric equipment load when gas is not available in the building

  • Scott Criswell Scott Criswell committed [r8634] on Code

    enum update adding backward compatibility for NEEA HPWH lists that are having 'JA13' removed (and moved to separate checkbox) - res tic #1384

  • Scott Criswell Scott Criswell committed [r2487] on Code

    enum update adding backward compatibility for NEEA HPWH lists that are having 'JA13' removed (and moved to separate checkbox) - res tic #1384

  • Scott Criswell Scott Criswell committed [r8633] on Code

    replace errant 2028 NPW weather files (<CZ>FSSP3A4*) files w/ an updated version 5 (<CZ>FSSP3A5*) - and corresponding rule source mod

  • Scott Criswell Scott Criswell committed [r2486] on Code

    replace errant 2028 NPW weather files (<CZ>FSSP3A4*) files w/ an updated version 5 (<CZ>FSSP3A5*) - and corresponding rule source mod

  • Scott Criswell Scott Criswell committed [r2485] on Code

    CBECC 2022/25 (1357) executables w/ updates to CUAC (2022) and 2025 weather testing (2028 wthr file selection)

  • Scott Criswell Scott Criswell committed [r2484] on Code

    fix to 2025 Standard design PV sizing - switched from the Jul-23 version that adjusted for proposed HVAC EER back to the original that is consistent w/ the final '25 standard

  • Scott Criswell Scott Criswell committed [r8631] on Code

    add 2 new sets of 2028 weather data for analysis and comparison - population-weighted and non-population-weighted files using SSP3-7.0 (version 4, from E3)

  • Scott Criswell Scott Criswell committed [r2483] on Code

    add 2 new sets of 2028 weather data for analysis and comparison - population-weighted and non-population-weighted files using SSP3-7.0 (version 4, from E3)

  • Scott Criswell Scott Criswell modified ticket #1318

    Air-to-Water Heat Pump Compliance Option

  • Scott Criswell Scott Criswell committed [r8626] on Code

    CBECC 2022/25 and new CBECC-CLI (command line executable) EXEs (1357) to enable completely UI-free CBECC rule compilation and analysis (associated w/ the new GitHub testing framework)

  • Scott Criswell Scott Criswell committed [r8625] on Code

    CBECC 2022/25 (1356) executables and ruleset source enabling projects to run w/ residential common areas and no dwelling units (tic #3630)

  • Scott Criswell Scott Criswell committed [r8622] on Code

    revisions to clarify that res central DHWSys recirc pump power is a total value, spanning all loops - user support gh issue #37

  • Scott Criswell Scott Criswell committed [r8621] on Code

    added a few 2025 sample models (88 unit FlrMult and 8 & 88 unit VCHP3) - and added error check preventing res central VRF system models due to incompatibility of CSE RSYS VCHP2 type in this latest CSE executable

  • Scott Criswell Scott Criswell committed [r8620] on Code

    T24Res lookup table XLSX including VCHP3 tables tab

  • Scott Criswell Scott Criswell committed [r8619] on Code

    updated CSE (0.922.1.0+perfmap...) and ruleset mods enabling VCHP3 (HeatPumpV3) selection and analysis

  • Scott Criswell Scott Criswell committed [r8618] on Code

    create branch to facilitate testing of the VCHP3/HeatPumpV3 (CSE) heat pump model/simulation

  • Scott Criswell Scott Criswell committed [r8617] on Code

    ruleset update migrating Harvest Thermal (HeatPumpDHWCombo) system and other features (bug fixes & VCHP3) from CBECC-Res into CBECC (tic #3629)

  • Scott Criswell Scott Criswell committed [r8614] on Code

    revised rule setting screen label (Proj:ReducedPVReqMsg2) to document scenario where SARA-based capacity exceeds prescriptive, therefore reduced requirement not applied (despite user input) (user support gh #37)

  • Scott Criswell Scott Criswell committed [r8613] on Code

    ruleset mod to establish a minimum value of 1 for ResDHWSys:NumFloorsServed (user support)

  • Scott Criswell Scott Criswell committed [r2481] on Code

    updates to HeatPumpV3 (VCHP3) 2D performance property interpolation tables and setting of CSE cycling factors (CdC & CdH) by HP speed (variable vs. single-speed)

  • Scott Criswell Scott Criswell committed [r8612] on Code

    ruleset fixes & improvements

  • Scott Criswell Scott Criswell committed [r8611] on Code

    OS_Wrap25.dll update that prevents openStudio from creating EnergyPlus Spaces

  • Scott Criswell Scott Criswell committed [r8610] on Code

    CBECC 2022/25 (1355) executables and ruleset source w/ various CUAC and T24 analysis fixes/improvements

  • Scott Criswell Scott Criswell posted a comment on ticket #1378

    latest CUAC updates checked into CBECC-Res SVN @ rev 2478, including: (1) checkbox to toggle off DHW and ability to specify % of PV system (described above) (2) updated rate download mechanism, and (3) fixes re: CUAC analysis on models using Propane fuel and rates

  • Scott Criswell Scott Criswell committed [r2478] on Code

    CBECC-Res 2022/25 (1355) executable and rule update w/ CUAC fixes - energy use and utility bills for Propane projects + utility bill download container

  • Scott Criswell Scott Criswell committed [r2477] on Code

    CBECC-Res 2022/25 (1354) executables w/ fix for crash related to excluding DHW from CUAC in mixed fuel bldgs - also some heatPumpV3 updates

  • Scott Criswell Scott Criswell committed [r8607] on Code

    CBECC 2022/25 (1352) executables w/ latest (EPlus 24-1) OpenStudio library DLL

  • Scott Criswell Scott Criswell committed [r2476] on Code

    CBECC-Res 2022/25 (1354) executables and rules fixing VCHP3 autosizing issue and adding percent PV system allocation for SFam CUAC analysis

  • Scott Criswell Scott Criswell committed [r2475] on Code

    CBECC-Res rules and UI enabling HeatPumpV3 autosizing (requires activation of EnableHPAutosize INI flag)

  • Scott Criswell Scott Criswell committed [r2474] on Code

    CBECC-Res 2022/25 (1353) w/ updated CSE - HeatPumpV3 and CUAC updates

  • Scott Criswell Scott Criswell posted a comment on ticket #1378

    Updates requested as of check-in call earlier today - (1) add checkbox to the project-level CUAC dialog tab enabling the user to toggle OFF inclusion of DHW in CUAC calcs (similar to that in CBECC @ the Zone level), and (2) add in out for Percent PV System Allocated to the project-level CUAC dialog tab, capped at and defaulting to 100% - enabling user to indicate that only a portion of the PV system described in the Project/PV tab is to be allocated to the CUAC unit/analysis. Once these changes are...

  • Scott Criswell Scott Criswell posted a comment on ticket #1371

    What I believe Danny/CEC is saying above is that users should only see and select in the UI SANCO2 options. This alone says nothing about backward compatibility. I believe we still need full backward compatibility - Users of future CBECC-Res releases need to be able to import prior release models (that may include Sanden references) and those models should be recognized and updated to SANCO2 in the upcoming & future releases. This we covered earlier in our call. Likewise - users in the future should...

  • Scott Criswell Scott Criswell committed [r8605] on Code

    CBECC 2022/25 (1352) executables with rules processor (2D interpolation lookup table) features and 2028 SSP2 & SSP3 weather files and ruleset/UI updates enabling their test

  • Scott Criswell Scott Criswell committed [r2473] on Code

    CBECC-Res 2022/25 (1352) executables w/ HeatPumpV3 updates (still in progress) and 2028 weather and testing features

  • Scott Criswell Scott Criswell committed [r2472] on Code

    CBECC-res 2022/25 (1351) executables w/ PV Export results (kWh/yr & %) for Prop & Std models appended onto end of summary results CSV records (cols NN-NQ)

  • Scott Criswell Scott Criswell committed [r8603] on Code

    MFam user support fix - prevent activating StdDsgnSolarSysReqd (std design solar thermal system) for ResDHWSys systems that are NOT 'New' (such as Altered)

  • Scott Criswell Scott Criswell committed [r2471] on Code

    CBECC-Res 2022/25 (1350) executables and rule/screen source w/ updated CSE (7/18, VCHP3 heating autosize fixed) and fixes/improvements to VCHP3 (HeatPumpV3) system

  • Scott Criswell Scott Criswell committed [r2470] on Code

    CBECC-Res 2022/25 (1350) ruleset mods renaming NEM type NEM3 to NEM3-LSC and adding new NEM3-ACC option

  • Scott Criswell Scott Criswell committed [r8602] on Code

    CBECC 2025 (1350) executables and ruleset & UI source w/ addition of NEM3 adjustments to LSC results for exports (of elec) to the grid

  • Scott Criswell Scott Criswell committed [r8601] on Code

    OpenStudio library DLL update fixing 2025 (new EPlus 24.1) errors in SMT sample models

  • Scott Criswell Scott Criswell committed [r8600] on Code

    EnergyPlus/OpenStudio update to ver 24.1 - 8 of 11 Std Model Test samples throw E+ errors

  • Scott Criswell Scott Criswell committed [r8599] on Code

  • Scott Criswell Scott Criswell committed [r8598] on Code

    fix problems introduced in rev 8596 related to tracking floor area served for ResDHWSystems (include only ResOtherZns w/ water heating load) and ResWtrHtrs (include ResOtherZn area regardless of cond/uncond setting)

  • Scott Criswell Scott Criswell modified ticket #3606

    MF: Unable to Assign Existing ResDHWSys to both Common Areas and Dwellings

  • Scott Criswell Scott Criswell posted a comment on ticket #3606

    ruleset fix checked into SVN @ r8596 - fixed problem in setting of ResDHWSys:ExFlrAreaServed, AltFlrAreaServed & NewFlrAreaServed to ensure that nonres (ResOtherZn) assigned DHW floor area was properly categorized based on ResOtherZn:DHWSysStatus

  • Scott Criswell Scott Criswell committed [r8596] on Code

    Fix problem where Existing ResDHWSys objects assigned to both (existing) ResOtherZn(s) and ResZn(s) (via DwellUnitTypes) in EAA MFam projects were throwing errors indicating that the system was assigned to a combination of New & Existing zones (tic #3606)

  • Scott Criswell Scott Criswell created ticket #3606

    MF: Unable to Assign Existing ResDHWSys to both Common Areas and Dwellings

  • Scott Criswell Scott Criswell committed [r8593] on Code

    CBECC 2022/25 (1348) executables and ruleset update w/ several misc fixes -

  • Scott Criswell Scott Criswell modified ticket #1378

    Implement Single Family CUAC (Cal. Utility Allowance Calculator)

  • Scott Criswell Scott Criswell posted a comment on ticket #1378

    Initial CUAC functionality checked into SVN @ revs #2462 (5/17) & #2468 (6/4) - - initial complete version requires more testing and does not yet include (a) import of CUAC projects for old MS Acccess databases, (b) Tools menu bar options to open CUAC report PDFs, and (c) possibly offering CUAC analysis for ADU and/or EAA projects Final/complete mods checked into SVN @ rev #2469 (6/14), including - option to import old (Access database) CUAC project data for analysis in CBECC-Res (note: import &...

  • Scott Criswell Scott Criswell committed [r2469] on Code

    CBECC-res 2022/25 (1348) executables and ruleset/screen source including new CUAC analysis functionality (tic #1378)

  • Scott Criswell Scott Criswell committed [r2468] on Code

    CBECC-Res 2022/25 (1347) executables, screen definitions and ruleset mods enabling CUAC inputs and reporting in CBECC-Res 2022.2.0 Example Files.zip(tic #1378)

  • Scott Criswell Scott Criswell committed [r8590] on Code

    ruleset mod preventing simulation of ResOtherZn PrkgGarExhFlow & PrkgGarExhFanPwr when SpcFunc NOT one of the 'Parking Garage...' options

  • Scott Criswell Scott Criswell committed [r2467] on Code

    revisions to VCHP3 defaulting and CSE input generation (plus activation of more CUAC stuff)

  • Scott Criswell Scott Criswell posted a comment on ticket #1378

    Another question for CEC/Contractors - 4) The CBECC implementation includes a fairly detailed PV allocation to assign fractions of the building PV system to individual dwellings (apartment types). For single dwelling analysis, is it OK to assume that the entire PV/battery system applies to the CUAC analysis? And if Q3 above answer indicates multiple CUAC results (main home + ADU), would we then need a PV allocation mechanism?

  • Scott Criswell Scott Criswell committed [r2466] on Code

    latest CSE update - v0.922.1+perfmap.2f0f13a8.25

  • Scott Criswell Scott Criswell committed [r2465] on Code

    ruleset and screen mods to enable VCHP3 specification & analysis in 2025 code (was previously tested/debugged in 2022)

  • Scott Criswell Scott Criswell committed [r2464] on Code

    CBECC-Res 2022/25 (1346) executables and rule source w/ VCHP2 update (tic #1379)

  • Scott Criswell Scott Criswell modified ticket #1379

    VCHP3 Equipment Simulation (based on NEEP statistical model)

  • Scott Criswell Scott Criswell posted a comment on ticket #1379

    Updates checked into SVN @ r2463 are ready for testing. What is currently included are: - VCHP3 performance curves produced based on user input capacities & efficiencies, consistent w/ spreadsheet model from BigLadder - fan powers of 0.281 W/CFM for ducted and 0.171 for un-ducted systems - CSE update (0.922.1+perfmap.9a585fb6.20) w/ full input processing (& partial error checking) and simulation based on latest discussions & spreadsheets Upcoming changes: - likely fixes/updates to CSE simulation...

  • Scott Criswell Scott Criswell committed [r2463] on Code

    VCHP3 rule mods instituting fan powers of 0.281 W/CFM for ducted and 0.171 for un-ducted systems (tic #1379)

  • Scott Criswell Scott Criswell committed [r2462] on Code

    CBECC-Res 2022/25 (1345) executables (incl. CSE update) and ruleset source w/ first round of new VCHP3 system type inputs & processing (tic #1379) plus partial port of CUAC from CBECC (tic #1378)

  • Scott Criswell Scott Criswell committed [r8586] on Code

    ruleset fixes for user support - divide-by-zero error w/ dwelling zone having NO windows -and- prevent CSE error: whEF (0.98+) must be <= 0.98 when whHeatSrc=ResistanceX

  • Scott Criswell Scott Criswell committed [r8585] on Code

    ruleset fix removing doMainSim = "No" from annual CSE runs when Proj:HVACAutoSizing is activated

  • Scott Criswell Scott Criswell modified ticket #1379

    VCHP3 Equipment Simulation (based on NEEP statistical model)

  • Scott Criswell Scott Criswell created ticket #1379

    VCHP3 Equipment Simulation (based on NEEP statical model)

  • Scott Criswell Scott Criswell posted a comment on ticket #1378

    Questions for CEC/Contractors - 1) Restrict to New Cons & EAA, but not addition alone, since that does not represent an entire home model? 2) Disable CUAC if 'No dwelling unit' checked -or- 'Proj... includes kitchen' is UNchecked on the Analysis tab? 3) Disable CUAC for projects w/ ADUs -or- report a project w/ ADU as a single dwelling unit? (we don't have an effective way to separately meter home vs. ADU unless user separates out zoning and HVAC & DHW systems)

  • Scott Criswell Scott Criswell committed [r8584] on Code

    CBECC 2022/25 (1344) executables w/ fix to local time (DST) labeling in CBECC hourly results export CSVs

  • Scott Criswell Scott Criswell created ticket #1378

    Implement Single Family CUAC (Cal. Utility Allowance Calculator)

  • Scott Criswell Scott Criswell committed [r8583] on Code

    ruleset source and binaries consistent w/ UPDATED 2022.3.1 (8583) release

  • Scott Criswell Scott Criswell committed [r8582] on Code

    port recent NRes/Res SARA updates from 2022 to 2025 (tic #3596) - plus add 'Project-ComplianceFormsMultiFamily.rule' to 2025 rules to fix analysis errors there

  • Scott Criswell Scott Criswell committed [r8581] on Code

    CBECC 2022/25 (1343) digitally signed executables, mfam sample projects, ruleset source and binaries consistent w/ 2022.3.1 release

  • Scott Criswell Scott Criswell committed [r2461] on Code

    CBECC-Res 2022/25 (1343) digitally signed executables, sample files and ruleset source/binaries consistent w/ the 2022.3.1 release

  • Scott Criswell Scott Criswell committed [r8576] on Code

    REVERT all 2022 MFam sample, sensitivity, ruleset, prototype, etc. models to prior version due to issue w/ bulk Spc:OccSensorCtrl = 1 mod

  • Scott Criswell Scott Criswell committed [r8573] on Code

    All 2022 sample, sensitivity, ruleset, prototype, etc. models updated to include Spc:OccSensorCtrl = 1 (to prevent check code errors during analysis)

  • Scott Criswell Scott Criswell modified ticket #1369

    Generic HPWH enhancement

  • Scott Criswell Scott Criswell posted a comment on ticket #1369

    compliance reporting XML schema and program output and PDF generation all confirmed to include the new tier 4 NEEA HPWHs - which concludes work on this topic for the 2022.3.1 release. Remaining to be done for 2025 analysis - new generic federal minimum HPWH in storage capacity of 65 gallon and 80 gallon.

  • Scott Criswell Scott Criswell committed [r8567] on Code

    add rule to force re-default of ResWtrHtr:TankVolume for NEEA HPWHs to ensure reporting accuracy

  • Scott Criswell Scott Criswell committed [r8566] on Code

    ruleset mods to ensure output of DistMF* for Res VCHP systems w/ certified fans (gh tic#144)