Hi, i am acquiring data via LabChart but i cannot find a way to export them in a format readible by Ledalab. Can somebody help me out please? is there a software also that can help me analize HR data? i really do not know hot to solve this problem. Thank you in advance for help
thank you Mathias, the negative values are in the first file attached on the 28 of dec, while for the rest of the files the CDA analysis gives no results as you can see in the last file attached ADIT144. Each file is down sampled to 10Hz and an adaptive smoothing filter has been applied. Is this due to the downsampling too small? thank you in advance
thank you very much Mathias. it is still not clear though, the values that i see refer to the mean calculated on 300 seconds? plus, why do i have negative values? and why in some files , i have almost no results? find file attached
thank you very much Mathias. it is still not clear though, the values that i see refer to the mean calculated on 300 seconds? plus, why do i have negative values?
hi, i am using last Ledalab version but when i save the results file with z score nothing appears on the excel file. could u help me to undesrand why, please? i found as well a negative amplitude of the SCR if i see at the TTP analysis results , how can this be possible? i attach here one of the file as example thank you for the help in advance
hi all, i am trying to analyse with CDA my baseline session which lasts 300 seconds. i have 1 event at the beginning. i export the parametersby setting the window from 0 to 300 seconds. When i export the results, on the CDA sheet appears only 1 row despite the number of SC responses are shown to be 27. So my question is : as only one line of results appears, does the value about Phasic activity , tonic activity etc etc refer to the mean of all the 27 peaks found in 300 seconds or it refers to the...
hi, i am using last Ledalab version but when i save the results file with z score nothing appears on the excel file. could u help me to undesrand why, please? i found as well a negative amplitude for the TTP analysis , how can this be possible? i attach here one of the file as example thank you for the help in advance
hi all, i am trying to analyse with CDA a 300 seconds file with 1 event at the beginning. i export the parameters for a window from 0 to 300 seconds. When i export the results, on the CDA sheet appears only 1 row despite the number of SC responses are shown to be 27. So my question is : as only one line of results appears, does the value about Phasic activity , tonic activity etc etc refer to the mean of all the 27 peaks found in 300 seconds or it refers to the first peak found anfter the event?...