Hi, This comes from InterSession, a session manager that has been around since the late 1980s. It runs on "all" IBM os'es, zOS, zVSE and zVM. We have our own tn3270(e) server that was added about 15 years ago. There is no VTAM session between the terminal and the session manager, just tn3270(e). The bind image we provide over tn3270e when asked for it is the image we construct. I agree the BINPRESZ byte should probably be set to X'7F' instead. I suspect no other tn3270 emulator looks at this byte....
Hi, Sorry for the delay, has been busy with other stuff. From the trace: 20220429.184339.223 Host socket read complete nr=33 < 0x0 030000000031010303b190308000008787000002800000000018502b507e00ff < 0x20 ef 20220429.184339.224 RCVD TN3270E(BIND-IMAGE NO-RESPONSE 0) < BIND PLU-name '' MaxSec-RU 1024 MaxPri-RU 1024 Rows-Cols Default 24x80 Al ... ... ternate 24x80 18502b50 are the screen sizes.24x80 and 43x80. BUT when printed it becomes 24x80 and 24x80. I think that's where the problem is. Best regards,...
I was using "the latest", both x3270/c3270 downloaded vid "apt install..." (yesterday) in ubuntu 20.x and wx3270 downloaded (yesterday) from a link i found in the wiki, all with the same behaviour. The windows file used for installation was "wx3270-1.0ga9-setup.exe", I don't have access to the ubuntu computer at this moment. Attached is a trace taken with wc3270. Best regards, Torbjörn Svensson Den tors 28 apr. 2022 kl 17:47 skrev Paul Mattes pmattes@users.sourceforge.net: Can you tell me which version...
3270 datastream not rendered correctly