Sent you a mail. Best Wolf
Send you a mail. Best Wolf
Hi Robert, I made a new device based on the latest documentation (121-7), in addition with all the fixes from the discussion board (voltage regulator etc.). Im using the SparkFun weather station including the rain bucket gauge. In operation it seems there is some noise in the signal line. The rain bucket shows fantastic amounts of rain. After ten minutes of operation it shows 2500 l/m² during dry weather. As a first shot, I tried the 1 M Ohm pull down between signal and ground from Document 119-6,...
Hi Robert, perfect! Thank you and best regards Wolf
Hi Robert, yeah in the row RainVolts its showing 3, but the 0,3 volts is moved to the next row. When you import in to Excel, the NELM value (the next row) is showing 3. So all values are shifted 1 row to the right. See attachment. Best Wolf
Hi Robert, yeah in the row RainVolts its showing 3, but the 0,3 volts is moved to the next row. When you import in to Excel, the NELM value (the next row) is showing 3. So all values are shifted 1 row to the right. See attachment. Best Wolf
It's the data-log. See attached file. Here "RainVolts". Best regards Wolf
Hi Robert, The problems I wrote bout in an earlier version of this post, were induced by an faulty TLS2591 sensor. After changing the sensor the software works now as planned. Sorry! There is a small issue with the log files. In the data-log-file the voltage from the rain sensor uses a comma instead a decimal point like the data from the other sensors. That makes confusion when using the data in Excel etc. Best Wolf