This is a script simulating a circuit consisting of 2 battery voltage sources and a load.

Voltage sources used are a 14S Samsung INR21700-50G OCV function
and a genereic Lead Acid 48V OCV function.

This script assumes a fixed internal resistance over the whole SOC range.
Sources are charged to 54.5V float voltage.
Results are shown in 2 separate graphs.

Features

  • Simulating parallel voltage sources
  • Based on a fixed internal resistance R0(t)
  • Based on equations attached in picture.