2610 unit tests plus 14 integration checks. From 1.10.x or later this installs from the Update button. On a PC that runs a building's HVAC controls, 1.16.1 raised almost nothing but BACnet, and the desktop window barely opened or scrolled, with monitoring on or off. The browser dashboard was fine. Each fix has tests that fail on 1.16.1.

  • A BACnet setting. Settings → Building automation (bacnet.mode):
  • Watch it, the default and what NetSentinel did before: discovery from another computer, writes and device resets are alerts.
  • This PC runs the building's controls: its own discovery, polling and writes are expected, and BACnet is not listed as an unencrypted service. Resets, and writes from any other computer, are still alerts.
  • Off: BACnet is left out of the capture, so none of it is even read. If you added not udp port 47808 to capture.bpf_filter as a stopgap, take it out and use the setting.
  • No more BACnet "credentials". Every controller answering discovery was stored in the vault as a credential, and alerted as "[CONFIRMED] Plaintext Credential (BACnet)": filed under the broadcast address, with the source port shown as 0, saying to change a password nobody had sent. BACnet and Modbus write commands were filed as credentials too. None of them holds a secret. A controller that announces itself is now a building controller in the device list, and a write is a finding only. What was filed that way before is dropped from the vault and the Exposures page when NetSentinel starts.
  • A broadcast address is no device. Controllers answer discovery to the broadcast address, which became an "Unencrypted BACnet Service" of its own.
  • The desktop window keeps up. Timed on the real window:
  • The Forensics Vault drew every entry as its own row of widgets, a second after the window opened: 10 seconds for 500 entries, about 3 minutes for 5,000, with the window frozen throughout. It is a table now, newest first (under a tenth of a second), loaded when you open the tab.
  • Each alert was a block of a dozen widgets, and the dashboard rebuilt its five most recent for every new one: 0.3 to 0.55 seconds of frozen window per alert, and a building network raises them by the hundred. The Alerts tab, the dashboard's recent alerts and the File Analyzer's list are tables now, and new alerts are added twice a second in one batch: 4 to 25 ms an alert, a burst of 300 in 29 ms. With 5,000 stored alerts the window opens in under a second instead of 3.3, and the Alerts tab lists the latest 1,000, not 200, with an Ack column.
  • The Devices, Exposures, Incidents and Capture tabs rebuilt themselves every five seconds whether shown or not. Now only the one on screen does.
  • Open in vault. A credential alert's window and a plaintext login on the Exposures page open the vault at that entry, to see what was actually caught. By default the vault keeps only the masked value; the full one only with forensics.store_raw_credentials on.

Installing. Install Npcap first (tick "WinPcap API-compatible mode"), then run NetSentinel.exe. It asks for administrator rights because packet capture needs them; from 1.14.2 the prompt names the publisher, James Cupps, since the exe is code-signed. NetSentinel.exe.sha256 holds the checksum to verify the download, and NetSentinel.exe.sig the signature the built-in updater checks before installing.