Activity for VitalSignsCapture

  • John George John George posted a comment on discussion General Discussion

    I have a GUI prototype in mind using .NET MAUI like these attached images, still working on it: Regards, John.

  • John George John George posted a comment on discussion General Discussion

    In Mac OS X or Linux, you can "replay" the monitor binary serial stream using the .raw file generated by VSCapture, by creating pseudoterminals using socat and minicom packages. In the terminal use these example commands: socat -d -d pty,link=/tmp/virtualcom0,ispeed=19200,ospeed=19200,raw,mode=660 pty,link=/tmp/virtualcom1,ispeed=19200,ospeed=19200,raw,mode=660 Send the .raw file using minicom: minicom -D /tmp/virtualcom1 Connect VSCapture app to /tmp/virtualcom0 in serial port options and run the...

  • John George John George posted a comment on discussion General Discussion

    Dear Users, It's been a pleasure to collaborate and bring you the VSCapture project over the last several years. If you have benefitted from this project as individuals or companies, I'm sharing a link to support the open-source project through PayPal: https://paypal.me/vscapture?country.x=AE&locale.x=en_US This link will also be available via the project homepage. Thanks & Regards, John George K.

  • VitalSignsCapture VitalSignsCapture released /VSCaptureCLI/VSCaptureCLIv1.004Binary.zip

  • Romas Kizlaitis Romas Kizlaitis posted a comment on discussion General Discussion

    Dear John, Thank you very much for your support. Can't wait to try how your software works. I try different cables and options, I also ordered your recommended cable from conrad today, let's see. Btw, I have tried changing network settings to S/5, but this didn't help. Best regards, Romas

  • John George John George posted a comment on discussion General Discussion

    Hi Romas, As mentioned in this thread, a specific older ATEN chipset VID 0x0557 is needed for GE Carescape B650 USB RS232 data export. VSCapture doesn't support the LAN port as it runs on a different protocol ?GE Sapphire network. I have not tried if changing the network type to MC or S/5 may have any effect on the LAN. One of the users from Germany shared this link to an older ATEN cable that worked for him: https://www.conrad.com/en/p/aten-usb-1-1-adapter-1x-d-sub-plug-9-pin-1x-usb-1-1-connector-a-uc232a-at-989235.html...

  • Davut GÜRBÜZ Davut GÜRBÜZ modified a comment on discussion General Discussion

    I heard that Aten changed their chipsets and the new chips we brought from dubai did't work for us. I got sample cables from Turkiye , brand is SLINK by segment computer https://www.segment.com.tr/en/product/s-link-sl-32t-usb-to-rs232-inverter https://www.segment.com.tr/en/product/s-link-swapp-sw-u610-siyah-usb-to-rs232-cevirici-kablo Some cables worked. I think Michael mentioned about chipset above. Regarding network interface I understood the communication, but GE informed me that it's their property...

  • Davut GÜRBÜZ Davut GÜRBÜZ posted a comment on discussion General Discussion

    I heard that Aten changed their chipsets and the new chips we brought from dubai did't work for us. I got sample cables from Turkiye , brand is SLINK by segment computer https://www.segment.com.tr/en/product/s-link-sl-32t-usb-to-rs232-inverter https://www.segment.com.tr/en/product/s-link-swapp-sw-u610-siyah-usb-to-rs232-cevirici-kablo Some cables worked. I think Michael mentioned about chipset above. Regarding network interface I understood the communication, but GE informed me it's their property...

  • Romas Kizlaitis Romas Kizlaitis posted a comment on discussion General Discussion

    Dear Michael, Did I understood correctly, you use USB to RJ-45 (RS-232) Console Adapter (UC232B) like described here: http://assets.aten.com/product/spec_sheet/uc232b_converter_ds_en.pdf? Could you explain, please, how you configure port and Capture data from ethernet with VSCapture software? Another question, GE B650 is not able to send data using its ethernet port, so I can capture it with VSCapture? Thank you

  • Michael Schiffer Michael Schiffer posted a comment on discussion General Discussion

    Yes I'm using the Serial USB ATEN to Ethernet path. I bought a couple of "old chipsets" ATEN converters form EBay they are working fine. If you look for e.g. Win 7 ready that should be an old one (good old times)

  • Romas Kizlaitis Romas Kizlaitis posted a comment on discussion General Discussion

    Dear Davut, Did you succeeded to explore ethernet option? I have ATEN converters, but they have new chipset, that's probably why I cant get any data from GE B650. Best regards, Romas

  • John George John George posted a comment on discussion General Discussion

    Hi Avinash, Please try the latest version of VSCaptureCLI from this site and check if this happens. Are you using RS232 MIB or LAN port? The LAN option is better for capturing high resolution data due to better bandwidth during rapid data transfer. In serial cables, FTDI chipset cables may be better. Please email me details of your setup and company to xeonfusion at yahoo dot com for further support. Regards, John.

  • Avinash D Avinash D posted a comment on discussion General Discussion

    Hello, We are having data loss issues with wave data when using vscapture software on Philips IntelliVue MX100 and MX550 models. The data is correct for the first 30 seconds but starts to lose accuracy after that. This happens with option 2 (ECG II, ABP, ART IBP, PLETH, CVP, RESP). If we capture data in 12-second intervals, the data loss is less. But after 2 minutes, data loss still happens, but it is less. The file name is NOM_ECG_ELEC_POTL_IIWaveExport.csv. Can you please help us understand why...

  • John George John George posted a comment on discussion General Discussion

    Hi Michael, The latest package that brings everything together, with all the updated modules is VSCaptureCLI (previously available as older individual modules). The drivers you may need is available in the CLI package, each device may have its own cable requirements and setup (search the discussions about this in this forum). To add new device drivers, please share the device communication protocol via mail. If you need more help, feel free to post or contact me at xeonfusion at yahoo dot com. Regards,...

  • Michael Wood Michael Wood posted a comment on discussion General Discussion

    Hi I've just found this project and I'm trying to figure out how it all fits together or what parts are relevant. Do you need the CLI and then the module specific to the device you want to capture data from? Or are the drivers for the different devices included in the CLI? Based on the contents of the CLI zip file I think everything is included. Also, could you point me to where the source code is available? Is there any documentation on how to go about adding drivers for more devices/protocols?...

  • Samuli Karvinen Samuli Karvinen modified a comment on discussion General Discussion

    Hi John, So the VSCapture itself already uses PDS Gateaway protocol, but we just need to get the monitor to send solicited HL7 messages via LAN, got it. I tried to setup both Central Station and ADT by giving them the PC's IP address and port 4601, but it did not work. However, on Page 386 In BeneVision N Series Operators Manual it says there should be a HL7 Configuration tab for HL7 messages between ADT and Information Security tabs in the monitor's Network settings, which actually might be the...

  • Samuli Karvinen Samuli Karvinen modified a comment on discussion General Discussion

    Hi, So the VSCapture itself already uses PDS Gateaway protocol, but we just need to get the monitor to send solicited HL7 messages via LAN, got it. I tried to setup both Central Station and ADT by giving them the PC's IP address and port 4601, but it did not work. However, on Page 386 In BeneVision N Series Operators Manual it says there should be a HL7 Configuration tab for HL7 messages between ADT and Information Security tabs in the monitor's Network settings, which actually might be the one we...

  • Samuli Karvinen Samuli Karvinen posted a comment on discussion General Discussion

    Hi, So the VSCapture itself already uses PDS Gateaway protocol, but we just need to get the monitor to send solicited HL7 messages via LAN, got it. I tried to setup both Central Station and ADT by giving them the PC's IP address and port 4601, but it did not work. However, on Page 386 In the Operator's manual (https://www.mindray.com/content/dam/xpace/en_gb/resources/downloads/education/education-nseries/operators-manual/BeneVision-N-Series-Operators-Manual.pdf) it says there should be a HL7 Configuration...

  • John George John George modified a comment on discussion General Discussion

    Try Central station or ADT network setup as in Pg 66 of the operator's manual. https://fcc.report/FCC-ID/ZLZ-WMTSN1/5287411.pdf#page66 Some of the options are to send unsolicited HL7 data to a server (not the option we want), but what the app actually requests is the solicited HL7 message. For these Mindray models, no additional software may be needed. The app directly requests data using the PDS Gateway protocol.

  • John George John George posted a comment on discussion General Discussion

    Try Central station or ADT network setup as in Pg 66 of the operator's manual. https://fcc.report/FCC-ID/ZLZ-WMTSN1/5287411.pdf#page66 Some of the options are to send unsolicited HL7 data to a server (not the option we want), but what the app actually requests is the solicited HL7 message.

  • Samuli Karvinen Samuli Karvinen modified a comment on discussion General Discussion

    Hi again John, I got my hands on the BeneVision N19 again (it was N19 instead of N22). I tried to find network settings where I could change the port to 4601, but I'm not really sure what the abbreviations stand for and there are two places where I can change port and they are in ADT and in MLDAP. My DHCP address is 202.114.4.1 and my the monitor's address is 202.114.4.119. How do I configure my monitor to open port 4601? Do I need additional software on my PC to use PDS Gateaway protocol? Sorry...

  • Samuli Karvinen Samuli Karvinen modified a comment on discussion General Discussion

    Hi again John, I got my hands on the BeneVision N19 again (it was N19 instead of N22). I tried to find network settings where I could change the port to 4601, but I'm not really sure what the abbreviations stand for and there are two places where I can change port and they are in ADT and in MLDAP. My DHCP address is 202.114.4.1 and my the monitor's address is 202.114.4.119. How do I configure my monitor to open port 4601? Do I need additional software on my PC to use PDS Gateaway protocol? Sorry...

  • Samuli Karvinen Samuli Karvinen modified a comment on discussion General Discussion

    Hi again John, I got my hands on the BeneVision N19 again (it was N19 instead of N22). I tried to find network settings where I could change the port to 4601, but I'm not really sure what the abbreviations stand for and there are two places where I can change port and they are in ADT and in MLDAP. My DHCP address is 202.114.4.1 and my the monitor's address is 202.114.4.119. How do I configure my monitor to open port 4601? Do I need additional software on my PC to use PDS Gateaway protocol? Sorry...

  • Samuli Karvinen Samuli Karvinen posted a comment on discussion General Discussion

    Hi again John, I got my hands on the BeneVision N19 again (it was N19 instead of N22). I tried to find network settings where I could change the port to 4601, but I'm not really sure what the abbreviations stand for and there are two places where I can change port and they are in ADT and in MLDAP. My DHCP address is 202.114.4.1 and my the monitor's address is 202.114.4.119. How do I configure my monitor to open port 4601? When running the VSCaptureCLI it says: Error opening/writing to TCP port ::...

  • John George John George posted a comment on discussion General Discussion

    Frequency depends on waveform (ECG has higher). For RR, it's probably a 16 sample array with sampling time of 16 msec and around 62.5 samples/sec. You can check manually the actual samples a second in your CSV file.

  • John George John George posted a comment on discussion General Discussion

    Hi Samuli, The first column in the Intellivue CSV export corresponds to monitor reported time, second column to monitor reported relative time and third to the System local time (of PC). Therefore, it is recommended to use the first or second columns to plot the actual time of the data generation (third time is affected by local CPU processing). There's no need to average the data. It's better to use the LAN port if possible to collect data reliably for any study. The sampling frequency depends on...

  • Samuli Karvinen Samuli Karvinen posted a comment on discussion General Discussion

    Hi John, Thank you for your quick reply! I will come back to this once I get my hands on the device again this week :) Best, Samuli

  • Samuli Karvinen Samuli Karvinen posted a comment on discussion General Discussion

    Hello, I tried recording with Philips IntelliVue X3 using VSCaptureCLI to acquire the data. I used these settings: Command line used for Philips Intellivue: -mode 2 -port -interval 1 -export 1 -waveset 2 -scale 2 Command line used for CLI: --devices -device1type 1 --device1model 1 --device1arg -mode 2 -port -interval 1 -export 1 -waveset 2 -scale 2 After the recording, I opened respiratory waveform data in MATLAB and extracted the 2nd column ("relative time") and 4th column (the recorded signal)....

  • John George John George posted a comment on discussion General Discussion

    Hi Samuli, You could trying changing the Network setup in the Maintenance menu of the monitor, to use the port 4601 (app uses the PDS Gateway protocol, make sure that is used) in solicited results interface. https://www.mindray.com/content/dam/xpace/en_us/service-and-support/training-and-education/resource--library/technical--documents/operators-manuals-1/H-0010-20-43061-1-Mindray-Patient-Data-Share-Solution-Guide-v14-03-2020.pdf Please post the screenshots of your configuration. Regards, John.

  • Samuli Karvinen Samuli Karvinen modified a comment on discussion General Discussion

    Hello, I need help in getting data out of Mindray Benevision N22. I am able to give it own IP-address with DHCP server on Windows 10, and I am also able to ping it on command line. Unfortunately, when I choose 'Mindray HL7' in VSCaptureCLI, it does not respond to any call. I have understood that Benevision N22 uses HL7 protocol, so what would be the issue? E.g. should I change the mode to maintenance or something? Thanks in advance!

  • Samuli Karvinen Samuli Karvinen posted a comment on discussion General Discussion

    Hello, I need help in getting data out of Mindray Benevision N22. I am able to give it own IP-address with DHCP server on Windows 10, and I am also able to ping it on command line. Unfortunately, when I choose 'Mindray HL7' in VSCaptureCLI, it does not respond to any call. I have understood that Benevision N22 uses HL7 protocol, so what would be the issue? Thanks in advance!

  • John George John George posted a comment on discussion General Discussion

    For GE S/5 Carescape monitors, that require connection via the USB port, I have wondered if anyone has tried using a direct USB to USB null modem cable https://ftdichip.com/products/usb-nmc-2-5m/. This way, one may not have to hook up a usb serial to a DB9 null modem cable, in turn hooked up to the PC side usb serial cable. But the chipset may have to be PL2303 based due to driver support on the monitor side.

  • David Inglis David Inglis posted a comment on discussion General Discussion

    yeah, in theory they should. We have tried others of the same spec with no joy. We have now ordered multiple of these ones.

  • John George John George posted a comment on discussion General Discussion

    Thanks David for sharing, that certain PL2303 chipset based USB serial cables, do work with the GE Carescape B650 model. The network settings should also be in S/5 data transfer mode.

  • David Inglis David Inglis modified a comment on discussion General Discussion

    sorry for the radio silence - have a small update. We have just bought anotjer cable and have found it works perfectly with the B650!! Note: we installed the recommended drivers from the cable manufacturers website Attached is a photo of the packaging so you can order

  • David Inglis David Inglis posted a comment on discussion General Discussion

    sorry for the radio silence - have a small update. We have just bought anotjer cable and have found it works perfectly with the B650!! Attached is a photo of the packaging so you can order

  • John George John George posted a comment on discussion General Discussion

    If it was previously connected to a central station, it may be better to restart the device, then set the IP address manually, make sure you are on the same subnet mask. Once you sort out the IP network issues, it should work.

  • Inbar Chityat Inbar Chityat posted a comment on discussion General Discussion

    If the monitor was previously connected to the hospital network but I disconnected it and connected it to my computer should there be any issue? I found the DHCP IP address defined in the monitor and used it, but it was the same when connected to the hospital network.

  • John George John George posted a comment on discussion General Discussion

    Make sure that the monitor is free of any other association, its IP address should be valid too. Internet sharing is for sharing your Wifi connection to your LAN port. In this way, the monitor connected to your LAN port (straight cable) gets a DHCP assigned IP address. You can also alternatively, assign an IP address manually to your LAN port settings in your OS (may work with a crosswire cable).

  • Inbar Chityat Inbar Chityat posted a comment on discussion General Discussion

    Hi John, Thank you for your answer. I started by connecting directly to the monitor through a LAN cable but that didn't work although I used the IP address I saw in the network settings in the monitor. Is the Internet sharing feature enabled a feature in the monitor that needs to be defined? Thank you, Inbar

  • Jay Jay posted a comment on discussion General Discussion

    Good day John, I've try to connect Computer to GE Monitor B650 in the operating room, but there has already connected to the central station. Is there any way to connect computer and the central station in the same time? Thanks

  • John George John George posted a comment on discussion General Discussion

    Hi Inbar, It's recommended to directly connect to the Intellivue LAN port using a crosswire or straight LAN cable (with the Internet sharing feature enabled) for the monitor to get a DHCP assigned IP address. Make sure you enter the correct IP address of the monitor. See: https://sourceforge.net/p/vscapture/discussion/general/thread/d87f964f/#32be If the central station is connected to the monitor another device/app can not associate or request data from the monitor. Make sure your monitor is directly...

  • Inbar Chityat Inbar Chityat posted a comment on discussion General Discussion

    Hi, I tried to acquire data using VScapture from Philips Intellivue. The monitor only had a LAN connection and when I tried to connect directly to the monitor the connection failed. I then tried to connect through LAN to the hospital network and managed to get data from a specific monitor, but it only worked once/twice in a row and then the connection failed again. Upon restart of the monitor, I could connect again through the hospital network and it worked once before failing again. Any insights...

  • VitalSignsCapture VitalSignsCapture updated /VSCaptureCLI/VSCaptureCLIv1.003Binary.zip

  • VitalSignsCapture VitalSignsCapture updated /VSCaptureCLI/VSCaptureCLIv1.003Binary.zip

  • VitalSignsCapture VitalSignsCapture released /VSCaptureCLI/VSCaptureCLIv1.003Binary.zip

  • John George John George posted a comment on discussion General Discussion

    VSCaptureBISVv1.002Binary improves support for EEG waveform capture from BIS Vista monitors via RS232 serial port. The "Vista Binary" serial data export should be enabled in the maintenance menu of the monitor. EEG Waveform CSV output can be converted into European Data Format (EDF) for further analysis and color DSA generation using the EDFBrowser app https://www.teuniz.net/edfbrowser/ and the ascii_to_edfEEG conversion template. After loading the template in EDFBrowser Tools menu (ASCII to EDF/BDF...

  • VitalSignsCapture VitalSignsCapture released /Cerebral Monitor/BIS Vista/VSCaptureBISVv1.002Source.zip

  • VitalSignsCapture VitalSignsCapture released /Cerebral Monitor/BIS Vista/VSCaptureBISVv1.002Binary.zip

  • VitalSignsCapture VitalSignsCapture released /Cerebral Monitor/BIS Vista/VSCaptureBISVv1.001Source.zip

  • VitalSignsCapture VitalSignsCapture released /Cerebral Monitor/BIS Vista/VSCaptureBISVv1.001Binary.zip

  • JJ.A. JJ.A. posted a comment on discussion General Discussion

    Hi, Thanks a lot for the explanation(and the app!). It is not essential for my applications to work with CSV, so I'll give the other options a try for now. If I ever think of something for this issue I'll make sure to run it by you though. Regards,

  • John George John George posted a comment on discussion General Discussion

    Hi JJ, This seems to be an issue with the Intellivue monitor exporting data with an irregular number of packets with each transmission. The approach I have taken to create a flat file structure like CSV is to use the RelativeTime attribute to group NumericValResults, hold it in memory till the next RelativeTime value comes across. If you need consistent header information for export to another application, a workaround is to use the JSON or MQTT export option. If you have any suggestions for the...

  • John George John George posted a comment on discussion General Discussion

    Unless we have the communication protocol documentation it's difficult to support the LAN access for GE B450. Older documents suggest that it uses the Carescape or sapphire network protocol.

  • zephyrusleaf zephyrusleaf posted a comment on discussion General Discussion

    Obtaining Vital Sign Data from GE B450 using the UDP Protocol,However, I am not sure how to parse the data. Does anyone know? Thank you.The attachment is the communication data obtained using Wireshark.

  • zephyrusleaf zephyrusleaf posted a comment on discussion General Discussion

    Obtaining Vital Sign Data from GE B450 using the UDP Protocol,However, I am not sure how to parse the data. Does anyone know? Thank you.The attachment is the communication data obtained using Wireshark.

  • JJ.A. JJ.A. posted a comment on discussion General Discussion

    Hello, I ran into a minor issue recently with the output CSV files, and figured the most efficient way to solve it would be to ask someone more competent ! For reference, I'm using VSCapture with a Philips IntelliVue MX800 connected via LAN port, and am currently exporting data in CSV, with 1 second interval and the "consolidated data list" option. I'm also exporting waveform data (option 8. & calibrated values). Most of the export files for the data MPDataExport look like this (with monitor in demo...

  • Paul David MacFarlane Paul David MacFarlane posted a comment on discussion General Discussion

    Thanks John, I ended up giving 'libSystem.IO.Ports.Native.dylib' writing permissions via preferences>security & privacy>full disk access which seemed to work before I saw your suggestion - many thanks!

  • John George John George posted a comment on discussion General Discussion

    Hi Paul, Glad you find the app useful. Please ensure that you unzip VSCapture to a folder with write permission enabled (ex: Downloads or Documents in Mac OS X). It should then be able to generate 2 files - a CSV file and a .RAW binary transcript of the serial communication (preserve both as .RAW contains the entire data sent by the monitor and can be used to debug any issues). Regards, John.

  • Paul David MacFarlane Paul David MacFarlane posted a comment on discussion General Discussion

    Hi - thanks for creating such a useful program! I've connected a Macbook pro running OS 12.74 to a datex S5 monitor have vscapture running via dotnet. I can see data in terminal, but cannot see any CSV files - I guess this is a write permissions issue but unsure how to resolve? I'd be very grateful for any advice! BW Paul "trans@eduroam-113-158 ~ % dotnet /Users/trans/Desktop/VSCaptureCLIv1.002Binary/VSCaptureWave.dll VitalSignsCaptureWave (C)2015-24 John George K. For command line usage: -help Select...

  • VitalSignsCapture VitalSignsCapture updated /VSCaptureCLI/VSCaptureCLIv1.002Binary.zip

  • VitalSignsCapture VitalSignsCapture released /VSCaptureCLI/VSCaptureCLIv1.002Binary.zip

  • John George John George created a blog post

    VSCaptureCLIv1.002 released

  • VitalSignsCapture VitalSignsCapture released /VSCaptureCLI/VSCaptureCLIv1.002Binary.zip

  • John George John George posted a comment on discussion General Discussion

    The pinout for GE S/5 monitors are attached below.

  • David Inglis David Inglis posted a comment on discussion General Discussion

    of course, I'll take a look today

  • Paolo Paolo posted a comment on discussion General Discussion

    Thanks, David, for all your support, not sure if this is too much to ask but could you please have a look at your Device configuration, the Host License option and check if the Network and Auto Alarm View is enabled?

  • Paolo Paolo posted a comment on discussion General Discussion

    Hi John, Thanks for your advice, in fact, there isn't any issue with the cable, if I connect them both to my computer I can send and receive data without any issue. I am afraid that the problem comes from the handshake between the computer and the monitor, I noticed that VSCapture does not send a message until the handshake is done, that could be the cause why a lot of people are getting problems with the communication with this monitor. I will keep an eye on it and keep everybody posted.

  • Xavier Gosset Xavier Gosset posted a comment on discussion General Discussion

    Hi John, Unfortunately, I cannot find anything regarding this. I checked all menu in the webmin interface and found no possibility to change anything regarding serial communication. Best Regards Xavier

  • John George John George posted a comment on discussion General Discussion

    The normal baud rate supported is 19200, but if 115200 is possible then it should be enabled in the service settings of the GE monitor, possibly serial/network settings. Please check the device or monitor user manual if this is possible. Let me know if you manage to do this!

  • Xavier Gosset Xavier Gosset posted a comment on discussion General Discussion

    Hi John, Thank you for the answer. In the iCollect documentation, they specify that it is possible to communicate with the monitoring at the speed of 115200 bit/s. Apparently, it seems we can request more waves in this case. I tryied without success. Did you already heard something about this? Regards Xavier

  • John George John George posted a comment on discussion General Discussion

    The app uses a command response serial communication with S/5 Datex protocol. There might be a cable issue if you are not getting data ouput. As mentioned in another thread, you also have to set the monitor data ouput to S/5 protocol and not the Carescape protocol.

  • John George John George posted a comment on discussion General Discussion

    Hi Xavier, The S/5 protocol limits the sampling rate for waveforms to 600 samples/second. Therefore, depending on the type of waveform (see image) the data ouput is limited to a supported combination. Regards, John.

  • Xavier Gosset Xavier Gosset posted a comment on discussion General Discussion

    Dear all, I'm trying to collect ECG 12 leads using a serial connection from a B450. I can collect the data but I'm not able to collect PLETH wave in parallel. Do you know if this is possible? Thank you. Xavier

  • David Inglis David Inglis posted a comment on discussion General Discussion

    I guess the issue could also be the cable you are connecting to your PC - we tried a few and one didn't work but the rest did Im using whatever the latest version from Github is and collecting CSV data, 5 seconds and only ECG.

  • Paolo Paolo posted a comment on discussion General Discussion

    Hi all, I am just trying to get data from a B650 monitor using VSCapture app, I am sing the latest version: VSCaptureCLIv1.001Binary. My issue is when I configure it to get the data but I get this message: Error opening/writing to serial port :: The write timed out. My questions are: 1) Do you know anything about this that can unblock my situation? 2) How does the system really work? I mean, if the device (B650 unit) sending data constantly and the VSCapture getting it or the VSCapture app instead...

  • Paolo Paolo posted a comment on discussion General Discussion

    Thank you very much David for all your support!, it is weird because we have the same configuration apparently, we even have same USB/Serial cable too (Vendor ID and so on) but we cannot read anything from the B650 unit yet from any USB port, could you please tell me what VSCapture app you are using and its configuration?

  • David Inglis David Inglis posted a comment on discussion General Discussion

    With regards to the cable - the one we got working is generic but it shows up on the monitor with the following details:

  • David Inglis David Inglis posted a comment on discussion General Discussion

    Alright. To enable S/5 data transfer, do the following: Plug a USB keyboard and mouse into the monitor Click on Monitor Setup Click on Service In the login screen, enter the username: biomed and password: Change Me (be aware this is VERY slow so be patient). Click Login (and wait) Click on configuration tab Click Network from left hand menu Click on Wired Interfaces (and wait) New screen should have some network info and a section below thay says Select Network Type Click on the box next to S/5 Click...

  • David Inglis David Inglis posted a comment on discussion General Discussion

    I'll post a how-to shortly 

  • Paolo Paolo posted a comment on discussion General Discussion

    Hi all, could you please describe the setting in network for S/5 to get data from the USB on a B650 monitor? Thanks

  • John George John George posted a comment on discussion General Discussion

    Draeger Vista120 monitor numeric data export is supported using the Draeger HL7 module in the latest version of VSCapture.

  • John George John George posted a comment on discussion General Discussion

    Hi David, That's great, can you share the exact model of the cable used and VID? The monitor data export protocol setting indeed needs to be set to the S/5 protocol. Please share your screenshots. Do PM me for any further queries and about your project at xeonfusion at yahoo dot com. Regards, John.

  • David Inglis David Inglis posted a comment on discussion General Discussion

    Ok. We have now made huge progress! After finding the setting in network for S/5 communication, we now have VSCapture working on a Carescape B650 on any USB port, using a cable that is NOT an ATEN cable. It is some generic PL2303 I think. So pleased to habe this working!

  • David Inglis David Inglis posted a comment on discussion General Discussion

    Thanks John. We have some PL2303 cables as well which also goce no results . Are there any settings on the monitor that could stop it transmitting? I have looked everywhere I can and can't see anything

  • John George John George posted a comment on discussion General Discussion

    One of the users from Germany shared this link to an online store (not verified) for the ATEN cable: The specific Model No is: UC-232A with the SN ZE8-040BP-2477 https://www.conrad.com/en/p/aten-usb-1-1-adapter-1x-d-sub-plug-9-pin-1x-usb-1-1-connector-a-uc232a-at-989235.html

  • John George John George posted a comment on discussion General Discussion

    There's a discussion about a similar issue with the change of chipsets (in an unrelated forum) corresponding to this vendor ID https://picaxeforum.co.uk/threads/ot-pl2303-with-different-vendor-id.25834/. These IDs may actually refer to PL2303 (Prolific) chipset based cables that are common in the market and not as good as the FTDI chipset based cables. You could try using PL2303 cables to see if it might work but the GE recommended cable is ATEN UC232A.

  • David Inglis David Inglis posted a comment on discussion General Discussion

    hi John. I hadn't considered asking ATEN actually - that's a good idea. I had hoped maybe GE had released new firmware that may have included more drivers but can't see anything.

  • John George John George posted a comment on discussion General Discussion

    Hi David, GE B650 monitors seem to have in built drivers only for the specific ATEN UC232A serial cable with chipset vendor ID 0x0557. Not sure if any other FTDI chipset based cable will work short of updating the monitor hardware (if thats even possible), trial and error. Have you tried contacting the manufacturer ATEN directly for the order? Example (doesn't specify the chipset): https://www.aten.com/global/en/products/usb-solutions/converters/uc232a/

  • David Inglis David Inglis posted a comment on discussion General Discussion

    hi all, we have recently taken delivery of a number of refurbished GE Carescape B650s and we are trying to record ecg data as we do on our old S/5 monitors I have read (I think) all of the treads on this and have just read the one which details that the ATEN usb-serial cable must have a specific hardware ID (which is now discontinued). The ATEN cable we boight via the links on the discussions has a hardware ID of VID 067B Is there any way that the B650 can be updated or is there any other way of...

  • Zunming Zhang Zunming Zhang posted a comment on discussion General Discussion

    Hi Evgenii, I am very interested in these documents. I was wondering if you could share these two documents with me. Thanks,

  • John George John George posted a comment on discussion General Discussion

    The author of EDFbrowser also provided this sample conversion template (attached) to convert CSV files generated by VSCapture into EDF files. The tool used to import CSV data is the ASCII to EDF conversion menu option under the Tools menu in EDFbrowser. A general guide for the conversion can be found here: https://www.teuniz.net/edfbrowser/EDFbrowser%20manual.html#ASCII_to_EDF_converter

  • John George John George posted a comment on discussion General Discussion

    Hi Alicia, There are many options. For general visualization of CSV data, use the scatter plot tool in MS Excel or similar tools. For more detailed analysis, researchers have used MATLAB, R, javascript or Python based software https://opensource.com/article/20/4/plot-data-python. It may also be possible to import CSV data into tools like EDFbrowser. https://www.teuniz.net/edfbrowser/ Regards, John.

  • Alicia Díez-Madroñero Manzano Alicia Díez-Madroñero Manzano posted a comment on discussion General Discussion

    Hello there, I am currently using VS capture to obtain ECG data from Datex s3 and S5 devices. However, I have been unable to visualize the data in order to interpret it afterwards. I was wondering if anyone has successfully visualised ECG data using this method and whether someone could provide me with some guidance or assistance. Best regards, Alicia.

  • Eugeny Eugeny posted a comment on discussion General Discussion

    Now I tries to reconstruct protocol Datex S/5 in a part of alarms transmission. I have some protocol dumps, I tries to recognize rules and structures

  • John George John George posted a comment on discussion General Discussion

    Thanks for sharing Gustav. We should collaborate for developing more drivers.

  • Gustav Magnusson Gustav Magnusson posted a comment on discussion General Discussion

    I just post this for anyone in the future who wants get data out of the philips MR400, I was able to use the Express data output format describe in the two document to get numeric data at 1Hz. Altough I was hoping to also record waveforms, these does not seem to be possible at the moment.

  • Eugeny Eugeny posted a comment on discussion General Discussion

    In VSCaptureWave source code I found public const short DRI_MT_ALARM = 4; //Alarm data and related transmission requests. It is data packed main type. I plan to send DRI_MT_ALARM for monitoring and investigate his response.