In the latest cvs checkout (05.26.03), all channels
show a flashing green line at the very top of the
display for me. This occurs when overscan is set at
either 0.0% or 0.5%. Anything higher then this is
fine. This occurs on all channels with any
deinterlacer. A screenshot of this behaviour is
here: http://142.163.75.64/~tourettes/tvtime-ss.jpg
Logged In: YES
user_id=153320
I checked in some 'fixes' that I think might cure this, but
I think the root cause is that there is some bad logic in
the deinterlacer code in tvtime.c about what pointers to
scanlines will be valid.
Logged In: YES
user_id=153320
Corey, is this still an issue? I think this should be fixed
in the released 0.9.8.4 version.
Logged In: YES
user_id=68182
It appears that the problem is now fixed in the latest release.
Thanks.
Logged In: YES
user_id=153320
Thanks for checking this out.