Menu

#425 If a multi-byte character is inputted, it will force to terminate.

All
closed
None
GUI
Windows
1
2014-11-04
2014-11-04
Anonymous
No

Hi Ben,
TaskUnifier has been a great product.
I have used the TaskUnifier in the Japanese environment.
If a multi-byte character is inputted into a new task or a search window, it will force to terminate.
Please help me resolve this since TaskUnifier is so crucial!

Thanks in advance.

Discussion

  • Anonymous

    Anonymous - 2014-11-04

    The problem was self-resolved.

    JRE 8u20 was the cause.

    JDK 8u20 Update Release Notes
    http://www.oracle.com/technetwork/java/javase/8u20-relnotes-2257729.html


    Area: client-libs
    Synopsis: JRE 8u20 crashes while using Japanese IM on Windows

    The VM crashes while using Swing controls when some Japanese or Chinese characters are input on Windows platform. There is no workaround.

    See 8058858 (not public).


    It was repaired, when updating to JDK 8u25 and reinstalling TaskUnifier.

    Please close this issue.
    Thank you.

     
  • Benjamin Leclerc

    Ok, good to know, thanks !

     
  • Benjamin Leclerc

    • status: open --> closed