For reasons I'd rather not got into, I want to use the library sepector tool on Windows nT4.

When I run it up, it complans that "CreateToolhelp32Snapshot could not be located in the dynamic link library KERNEL32.dll".

I reaslise that this is not a problem in WIn2k or XP (or Vista), but it still seems like a bug of sorts.

Any chance of a fix?

Discussion

  • Matt Wilson

    Matt Wilson - 2007-03-07

    Logged In: YES
    user_id=452543
    Originator: NO

    Will get to it at the weekend.

    Thanks for the heads up.

    Matthew

     
  • Matt Wilson

    Matt Wilson - 2007-03-07
    • priority: 5 --> 7
    • status: open --> open-accepted
     
  • Matt Wilson

    Matt Wilson - 2007-03-10
    • status: open-accepted --> closed-fixed
     