Section 3.1.3.5 and 6.2.1.1 of the PLM spec are not currently implemented. This ticket aims to implement them. For this we will just look at sensor events reported by HPI, and map them to alarms.

Related

Wiki: ChangeLog-5.19.07

Discussion

  • Alex Jones

    Alex Jones - 2019-04-04
    • status: accepted --> review
     
  • Alex Jones

    Alex Jones - 2019-04-09
    • status: review --> fixed
     
  • Alex Jones

    Alex Jones - 2019-04-09

    commit a954da73addf2c2cb4ed25c9360b1b687d580555 (HEAD -> develop, origin/develop, ticket-3027)
    Author: Alex Jones ajones@rbbn.com
    Date: Tue Apr 9 09:51:44 2019 -0400

     