OpenLCA's ecospold 1-export is missing mandatory fields, that are needed for importing data with ecoinvent's "ecospoldAccess" tool.
This report is a partial duplicate of bug No 42 but with additional information.
Some field are marked as "required" in the ecospold documentation (see file already provided here: http://sourceforge.net/p/openlca/bugs/_discuss/thread/071b63ed/c1d0/attachment/EcoSpold01Dataset.html) if these are missing, import with ecoinvent's "ecospoldAccess" Tool will fail.
-> These fields should be exported, even if their value is "false" or they are empty.
Missing fields are (non-missing fields omitted):
<dataset>
<metaInformation>
<processInformation>
<referenceFunction localName="", localCategory="", localSubCategory="", datasetRelatesToProduct="true" />
</processInformation>
<administrativeInformation>
<dataGeneratorAndPublication copyright="true/false" />
</administrativeInformation>
</metaInformation>
<flowData>
<exchange localName="", localCategory="", localSubCategory="", uncertaintyType=""> ( here the closing parenthese probably should be /> )
<dataset number="0"> should be <dataset generator="openLCA 1.3.4" number="1" timestamp="">
-> here, the two fields generator and timestamp are also missing
should be fixed with version 1.4.1 (beta7)