Normalizing constant algorithms use small perturbation at scale 1e-6 that produce results that differ at this scale with the MVA results. JMVA could use a smaller scale to avoid this inconsistency.
Scale 1e-5 seems to address the issue for RECAL and CoMoM. Reduction of random demands precision to 1e-3 makes it more unlikely that the problem is noticed by end users.
If you would like to refer to this comment somewhere else in this project, copy and paste the following link:
Scale 1e-5 seems to address the issue for RECAL and CoMoM. Reduction of random demands precision to 1e-3 makes it more unlikely that the problem is noticed by end users.
Only CoMoM is available as of 1.2.3-BETA1 so the issue is no longer open.