Menu

#1974 Wrong xtics positions with logscale

None
closed-duplicate
nobody
None
2017-10-06
2017-10-06
No

When using logscale, the <incr> of set xtics is supposed to be a factor, but with 5.2 the <incr> is treated as being additive:</incr></incr>

set logscale
set xrange [1:10000]
set xtics 100
plot 1/x
2 Attachments

Discussion

  • Ethan Merritt

    Ethan Merritt - 2017-10-06
    • status: open --> open-duplicate
    • Group: -->
    • Priority: -->
     
  • Ethan Merritt

    Ethan Merritt - 2017-10-06

    Yes. That was previously reported as Bug #1971

    Fixed in CVS and will be part of 5.2.1

     
  • Christoph Bersch

    Sorry I missed

     

    Last edit: Christoph Bersch 2017-10-06
  • Christoph Bersch

    • status: open-duplicate --> closed-duplicate
     

Log in to post a comment.