Menu

#312 Movie recording does not work for Timex modes

future
open
nobody
None
5
2014-08-16
2014-08-14
No

Choose Timex 2048, start movie recording, and type OUT 255,6.

Discussion

  • Sergio Baldoví

    Sergio Baldoví - 2014-08-15
    Choose Timex 2048, start movie recording, and type OUT 255,6.
    

    That should switch from a Timex standard screen to a Timex HiRes screen.

    This is simpler test with only HiRes screen:

    Choose Timex 2048, type OUT 255,6 and start movie recording.
    

    I've attached some patches that fix some bugs with HiRes screens. But display routines in fmfconv still need some fixes.

     
  • Sergio Baldoví

    Sergio Baldoví - 2014-08-16

    I've modernised display routines in fmfconv to handle HiRes screens.

    HiRes borders are still wrong because:
    - Border stored in display_last_screen use a different layout than main screen layout.
    - fmfconv don't differentiate between border and main screen.

    Display routines are being refactored in the ULAplus development, so I'm tempted to hold back these patches.

    The transition from a Timex standard screen to a HiRes screen doesn't work, picture of Timex standard screen is currently 320x240, whereas HiRes is 640x480.

     