#1398 2025-SFam: Prescriptive Refrigerant Charge

2025.1.0 RC
Verified
None
Critical
Comp.Error
2025
TBD
CBECCr
2025-05-14
2025-03-10
No

Update rules to require Refrigerant Charge for Heat Pumps across ALL climate zones (except for homes <= 500 ft2). (T24RClimateZoneCodeBaselines table still accurate for AC => req'd in CZs 2 & 8-15)
Confirm changes to defaults and standard design HPs.

Discussion

  • Thao Chau

    Thao Chau - 2025-03-12
    • Milestone: 2025 RV --> 2025 1.0 RV
     
  • Thao Chau

    Thao Chau - 2025-03-25
    • Priority: High --> Critical
     
  • Scott Criswell

    Scott Criswell - 2025-04-01
    • status: New --> Fixed
     
  • Scott Criswell

    Scott Criswell - 2025-04-01

    mods implementing this new prescriptive refrig charge standard design change checked into SVN @ r2554

     
  • Thao Chau

    Thao Chau - 2025-04-03

    For additions/alterations:

    1. HPs: Refrigerant charge verification is required for all CZs except for additions/alterations with less than 500 ft2.
    2. ACs: Refrigerant charge verification is required in CZ 1 and 8 – 15 except for additions/alterations with 500 ft2 or less.
     

    Last edit: Thao Chau 2025-04-03
  • Thao Chau

    Thao Chau - 2025-04-08
    • status: Fixed --> 80%Done
     
  • Scott Criswell

    Scott Criswell - 2025-04-09

    @ThaoChau - Re: Alteration requirement adjustments - is the check on '> 500 ft2' on just the Added (new) area, or the total home Cond area (or perhaps total area served by the new/altered HVAC system)?

     
  • Scott Criswell

    Scott Criswell - 2025-04-22

    final mods addressing latest comments checked into SVN @ r2570

    • ensuring refrigerant charge not verified for standard design of small new additions or altered homes (<= 500 SF)
     
  • Scott Criswell

    Scott Criswell - 2025-04-22
    • status: 80%Done --> Fixed
     
  • Trevor Thomas

    Trevor Thomas - 2025-04-23

    SVN 2570: I'm seeing refrigerant charge being triggered for heat pumps under all conditions even when <= 500 sqft. The default value in the GUI is also 'verified'. I've attached 2 of the files I've used. In case I set the files up incorrectly, or perhaps my SVN didn't fully update.

    These files are:

    A new construction 500 sqft home w/ heat pump
    An EAA model with a ~250 sqft addition w/ new heat pump

     
  • Trevor Thomas

    Trevor Thomas - 2025-04-23
    • status: Fixed --> 90%Done
     
  • Thao Chau

    Thao Chau - 2025-05-06
    • Milestone: 2025 1.0 RV --> 2025.1.0 RC
     
  • Scott Criswell

    Scott Criswell - 2025-05-14

    SVN 2577 -
    New cons 500 sqft home in CZ 5 w/ ductless, mini-split HP - Refrig charge NOT required in CZ5 - HVAC system type not supported, so Prop=Std HVAC. Both Prop & Std CSE simulation inputs indicate Refrig Charge not verified (RSYS rsFChgH = 0.9), however -
    Unrelated BUG - Proposed HVAC system should be identical to Std, but is NOT setup properly as PerfMap split HP (currently simulated as 'old style' split HP). Will fix this in association w/ tic #1379.
    EAA Example - 1,665 SF cond area home incl. 225 SF addition - new split HP serving only addition, w/ refrig charge verified. Std design is Verified because for an EAA model the check for <= 500 SF is on entire conditioned area, not just addition area or area served by HVAC system. Addition area is used in check for <= 500 SF only for Addition Alone projects.

    Pending review by CEC - no additional changes expected and ticket can be closed.

     
  • Scott Criswell

    Scott Criswell - 2025-05-14
    • status: 90%Done --> Fixed
    • assigned_to: Scott Criswell --> Trevor Thomas
     
  • Trevor Thomas

    Trevor Thomas - 2025-05-14
    • status: Fixed --> Verified