Currently when the user selects one of the generic tier 3 options, the SimulationGroup is being reported as AWHSTier3Generic40, 50, 65, or 80. Those values do not align with the Simulation Groups as defined in the base schemas for the compliance documents. There the groups are defined as Tier3Generic40, 50, 65, and 80.

The XML reporting should match the schema elements as defined in the compliance document base schema: Tier3Generic40, Tier3Generic50, Tier3Generic65, and Tier3Generic80.

8 Attachments

Discussion

  • Scott Criswell

    Scott Criswell - 2023-01-04
    • assigned_to: Scott Criswell --> Rob Hitchcock
     
  • Scott Criswell

    Scott Criswell - 2023-01-04

    Passing over to RH to handle - unsure whether recent NEEA (table) updates may have resolved this issue.
    Pass back to SAC if cannot be addressed by/before 1/11.

     
  • Rob Hitchcock

    Rob Hitchcock - 2023-01-04

    Rev 2316 revised XML reporting to match the schema enumeration strings.

     
  • Rob Hitchcock

    Rob Hitchcock - 2023-01-04
    • status: New --> Fixed
    • assigned_to: Rob Hitchcock --> Michael Shewmaker
     
  • Rob Hitchcock

    Rob Hitchcock - 2023-01-04

    Rev 2316 revised XML reported strings to match schema enumerations.

     
  • Michael Shewmaker

    • status: Fixed --> Verified
     
  • Michael Shewmaker

    Verified using 1284/2314 (svn @ r2317).

     