Remove 10 or more blades from the C700 Enclosure and reinsert them all quickly. For some of the the blades which are reinserted will have the resource tag as unknown.
This issue is seen frequently.
Steps to reproduce:
1. Remove the 10 or more blades from OA and reinsert all blades quickly.
2. Run the hpiinv or hpi_shell>inv
Actual output:
hpi_shell>inv
----
----
---
(058):HP ProLiant BL465c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(056):HP ProLiant BL460c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(059):HP ProLiant BL465c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(060):HP ProLiant BL460c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(061):[Unknown]:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(062):[Unknown]:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(063):[Unknown]:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(116):[Unknown]:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(065):HP ProLiant BL460c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(066):HP ProLiant BL460c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(067):HP ProLiant BL460c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(068):HP ProLiant BL460c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
Expected Results:
hpi_shell>inv
----
----
(056):HP ProLiant BL460c:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(058):HP ProLiant BL465c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(059):ProLiant BL465c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(060):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(061):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(062):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(063):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(116):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(065):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(066):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(067):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
(068):ProLiant BL460c G1:{S|RDR|INV|RST|PWR|FRU|CNT|HS|RES}
Ignore the events that come with Unknown values and wait for the complete event.
Fixed with version 7357