This project is an Open-Source (GPL) implementation of the SAE J1699-3 test specification. SAE J1699-3 test for compliance to OBD-2 protocols. THIS COMPUTER PROGRAM IS BASED UPON SAE RECOMMENDED PRACTICE J1699-3, WHICH WAS PROVIDED "AS IS".
License
GNU General Public License version 2.0 (GPLv2)Follow SAE J1699-3 Implementation Project
Other Useful Business Software
MongoDB Atlas runs apps anywhere
MongoDB Atlas gives you the freedom to build and run modern applications anywhere—across AWS, Azure, and Google Cloud. With global availability in over 115 regions, Atlas lets you deploy close to your users, meet compliance needs, and scale with confidence across any geography.
Rate This Project
Login To Rate This Project
User Reviews
-
对于phev车辆,通用分母计数条件是对车辆车速有要求,为何同时要求发动机转速不能为零?以及起发动机后为何消极应答04服务也会报错?
-
Test 5.14 (Verify Monitor Test Results (Service 06), Engine Running) frequently warning messages like below happened because the engine had been running for 80 seconds, after some of the Mode 06 data had already updated and repopulated. Especially for Test 5.8 PROMPT : let idle for one minute. WARNING message: ECU 7E8 SID 6 MID 41 test value/limits not reset please delete this message or change the procedure for Test 5.14.
-
Very useful. Thanks.
-
is it possible to use ETAS ES 6520 as interface for J1699 tests?