#5 Support for EG-PM2-LAN

Release 4.6
wont-fix
xypron
None
5
2020-03-10
2014-03-10
MartiniB
No

device has own web-if, BUT:
1. login method wget http://:passwd@10.0... doesn't work,
in the browser device asks only pass
2. http://10.0.0.217/status.html?sn=4 can show only status,
switching commands are implemented in java :(

device info:
http://www.energenie.com/service.aspx?item=7416&key=#item
some sources:
http://www.energenie.com/Repository/CommonFiles/cf_driver---3719da9c-31e0-4bb9-a958-a4b49b02e9a8.zip

Discussion

  • Vitaly Sinilin

    Vitaly Sinilin - 2014-08-16

    I found this discussion when I was looking for linux software for EG-PMS-LAN. Since I hadn't found anything except a curl-based script, I wrote an utility myself. I am not sure if it works for EG-PM2-LAN because I tested it on EG-PMS-LAN only. But if you still interested you can try it. In this case let me know whether it works for you or not.

    The source code is at https://github.com/unterwulf/egctl

     
  • MartiniB

    MartiniB - 2014-08-20

    THANKS Vitaly!!!
    EGCTL(EnerGenie Control) is brilliant solution

     
  • xypron

    xypron - 2018-11-18
    • status: open --> wont-fix
    • assigned_to: xypron
     
  • xypron

    xypron - 2018-11-18

    I have no access to that device. I would review and merge patches if provided.

     