#1975 Synergy blade added as rack mount server

3.8.0
closed-fixed
HPE Synergy plugin
5
2017-11-21
2017-10-11
dr_mohan
No

When a blade is removed and added back, the blade is removed well, but it gets added as a rack mount server. Immediately after removing and adding the blade, standby composer was removed and added too.

4 Attachments

Discussion

  • dr_mohan

    dr_mohan - 2017-10-11
     
  • dr_mohan

    dr_mohan - 2017-10-11

    Removed and inserted the active composer after that forcing a switchover. The removed blade got removed, but the RACK_MOUNTED_SERVER is still there in the hpitree output / RPT.

     
  • dr_mohan

    dr_mohan - 2017-11-21
    • status: open --> closed-fixed
     
  • dr_mohan

    dr_mohan - 2017-11-21

    We are unable to recreate the issue. May be it is fixed in oneview. As an work around we are adding an error message when this happens requesting customers to check the output and restart the daemon if needed.

     
  • dr_mohan

    dr_mohan - 2017-11-21
     
  • dr_mohan

    dr_mohan - 2017-11-21

    Fixed with checkin #7723