#1113 agentx subagent fails to handle multi-object request

closed
None
5
2012-11-09
2010-12-21
Bill Fenner
No

In a multi-varbind request, the agentx subagent fails to reset oid_len in the for loop, so if the first oid is shorter than the second one, the parse of the oid fails because the provided buffer does not appear to be large enough.

Discussion

  • Bill Fenner

    Bill Fenner - 2010-12-21
     
  • Wes Hardaker

    Wes Hardaker - 2010-12-29

    Thanks for the patch! It has been applied to the 5.3.x and later code branches and the main development tree, and will appear in future releases of the Net-SNMP package.

     