This begs the question: why does the Program Counter relays uses 2K (R204) instead of 100ohms? The data sheet for the relay stated the minimum relay pull-in voltage for a 12V relay to be 9.6V. If the nominal coil resistance is 1K (it's 960 +-10%) if R204 is 2K as spec'd, the relay sees 4V. So how is the relay supposed to engage with less than 50% of the specified pull-in? For reference, I was a Field Application Engineer for both Omron and Panasonic relays. I understand this 9.6V pull-in is a minimum,...