Oh, I just found the bad news about the author, never mind. RIP
Same problem again. 12 times it worked now since the last problem in May with the same kinds of blank disks. And on the 13th try today I am getting cdrecord: Input/output error. start/stop unit: scsi sendcmd: no error CDB: 1B 00 00 00 01 00 status: 0x2 (CHECK CONDITION) Sense Bytes: 70 00 04 00 00 00 00 0A 13 06 03 B4 B5 80 00 00 Sense Key: 0x4 Hardware Error, Segment 0 Sense Code: 0xB5 Qual 0x80 (vendor unique sense code 0xB5) [No matching qualifier] Fru 0x0 Sense flags: Blk 0 (not valid) cmd finished...
Same problem again. 12 times it worked now since the last problem in May. And on the 13th try today I am getting cdrecord: Input/output error. start/stop unit: scsi sendcmd: no error CDB: 1B 00 00 00 01 00 status: 0x2 (CHECK CONDITION) Sense Bytes: 70 00 04 00 00 00 00 0A 13 06 03 B4 B5 80 00 00 Sense Key: 0x4 Hardware Error, Segment 0 Sense Code: 0xB5 Qual 0x80 (vendor unique sense code 0xB5) [No matching qualifier] Fru 0x0 Sense flags: Blk 0 (not valid) cmd finished after 8.194s timeout 200s cdrecord:...
Same problem again. 12 times it worked now since the last problem in May. And on the 13th try today I am getting status: 0x2 (CHECK CONDITION) Sense Bytes: 71 00 03 00 00 00 00 0A 37 2D 03 B4 0C 00 00 00 Sense Key: 0x3 Medium Error, deferred error, Segment 0 Sense Code: 0x0C Qual 0x00 (write error) Fru 0x0 Sense flags: Blk 0 (not valid) cmd finished after 0.003s timeout 200s cdrecord: Input/output error. close track/session: scsi sendcmd: no error CDB: 5B 01 01 00 00 01 00 00 00 00 Then after restarting...
Same problem again. 12 times it worked now since the last problem in May. And on the 13th try today I am getting status: 0x2 (CHECK CONDITION) Sense Bytes: 71 00 03 00 00 00 00 0A 37 2D 03 B4 0C 00 00 00 Sense Key: 0x3 Medium Error, deferred error, Segment 0 Sense Code: 0x0C Qual 0x00 (write error) Fru 0x0 Sense flags: Blk 0 (not valid) cmd finished after 0.003s timeout 200s cdrecord: Input/output error. close track/session: scsi sendcmd: no error CDB: 5B 01 01 00 00 01 00 00 00 00 again. Then after...
Same problem again. 12 times it worked now ince the last problem in May. And on the 13th try today I am getting status: 0x2 (CHECK CONDITION) Sense Bytes: 71 00 03 00 00 00 00 0A 37 2D 03 B4 0C 00 00 00 Sense Key: 0x3 Medium Error, deferred error, Segment 0 Sense Code: 0x0C Qual 0x00 (write error) Fru 0x0 Sense flags: Blk 0 (not valid) cmd finished after 0.003s timeout 200s cdrecord: Input/output error. close track/session: scsi sendcmd: no error CDB: 5B 01 01 00 00 01 00 00 00 00 again. Then after...
Correction, this was a BD-R, not a DVD.
Hardware/Media/IO/sendcmd error