Hello, excuse me, I am not very strong in Linux. I did try to install Windows version, but cannot access the Web because Browser does not open the page and says "your connection to this site is not secure". But in any case I would like to run this on Ubuntu. I have running Ubuntu application in Windows. For me it looks like I followed all steps from "Installation" But where I do run the "server"? In a Terminal window? Where this executable is? Best Regards Gintautas
Hi, you should not apologies for anything, you do hard work. I know what is to keep the docs up to date :) I simulated different resistances for the divider and did a few tests with different nominal resistors. And found for this moment, that the best separation in ADC values at the toughest situation - E/ENE - (where the difference of the sensor resistance is smallest) is: R4 is shorted and R5 is 20k, 10k pull up. The values in the spreadsheet is using these nominals. In case of use R4 - 1k and...
Hi, So essentially there are 3 wires for Anenometer (gnd-pin1, 3,3v-pin2 and sig-pin3) and for the wind direction has two pins which are gnd-pin1 and sig-pin4. That is the wiring you have. That is not correct. The 80422 Anemometer and direction Sensor has no common wires on RJ11. Two wires for Anemometer and two for Direction sensor. You can check it at "'Home / Wind Direction Sensor / WINDDIRECTIONANALOG/SparkFun Assembly SEN-08942.pdf" and I attached the picture. But it is a Matter of external...
Forgot to mention once again - wind speed works in test only.
Hello Robert, the kit is from the Mouser: https://eu.mouser.com/ProductDetail/SparkFun/SEN-15901?qs=YwPsRIUVAOdCNLFQoffCEg%3D%3D It is the same Winddirection sensor as in "'Home / Wind Direction Sensor / WINDDIRECTIONANALOG/SparkFun Assembly SEN-08942.pdf" and the Windspeed sensor is from the same kit - it makes two contact closures in one rotation. I would like, if I may, to add a comment regarding connection of this Sparkfun kit. The RJ connector of the kit has 4 pins - 1 /4 for the Direction and...
Hello, I have a problem getting working this analog wind direction and speed device. FIRMWARE RELEASE 119-6. The direction sensor is defined as "#define WINDDIRECTION80422" in the "controllerconfig.h" as well as "#define WINDDIRECTIONSENSOR" is uncommented. I have correct directions displayed in Serial monitor when I use TEST_WINDDIRECIONANALOG script. The same values for the directions are entered in the "winddirection.h" I had 0 readings for the Direction in the web page until I have added "#define...
I mean the Aversge period setting in OCH. There is no need to change the Sample time in the mySQMPRO Arduino code. I do not know where these 30s refresh period in OCH comes from. May be it is from the mySQMPRO ASCOM driver. On Sat, 2 Nov 2019, 09:31 TomAstro, kamayok3@users.sourceforge.net wrote: setting in OCH? mySQM Ascom driver and Sequence Generator Pro https://sourceforge.net/p/arduinomysqmskyqualitymeter/discussion/general/thread/0bc74ead9e/?limit=25&page=1#81c9/06bc/f99e Sent from sourceforge.net...
I did not change sample time in the Arduino code. It works using these settings in the OCH so I do not change it in the code it is left as 5 s On Sat, 2 Nov 2019, 06:05 brownrb, brownrb@users.sourceforge.net wrote: yes mySQM Ascom driver and Sequence Generator Pro https://sourceforge.net/p/arduinomysqmskyqualitymeter/discussion/general/thread/0bc74ead9e/?limit=25&page=1#81c9 Sent from sourceforge.net because you indicated interest in https://sourceforge.net/p/arduinomysqmskyqualitymeter/discussion/general/...