Activity for Dee Anne Ross

  • Dee Anne Ross Dee Anne Ross modified ticket #1241

    XML Reporting: CHPWHs

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1241

    Last thing was to add the model number for small integrated to the brand (I messed up and forgot to include in the text version of the CF1R mock-up). Even the "Tank zone" was changed to reflect the zon name so I am very happy.

  • Dee Anne Ross Dee Anne Ross modified ticket #1003

    Treatment of room heatpumps and air conditioners

  • Dee Anne Ross Dee Anne Ross modified ticket #1227

    Missing equipment: Packaged gas furnace

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1227

    And I've since noticed it is happening on others.

  • Dee Anne Ross Dee Anne Ross modified ticket #72

    Add Radiant Barrier option for Cathedral Ceiling Construction

  • Dee Anne Ross Dee Anne Ross modified a comment on ticket #1226

    For both of these equipment types UI change needed: 1. CFM/ton remove the one on right (it is already on the left of the 350). CF1R/XML Changes: for SPVAC remove from HERS measures reporting (p. 3) Refrig Chg. HERS Verif Table set Refrig Chg to No. For SPVHP remove from HERS measures reporting (p. 3) Refrig Chg. HP Table add "n/a" to 17 degree cap. and SEER. HERS Verif Table set Refrig Chg to No and cap 17 to No.

  • Dee Anne Ross Dee Anne Ross modified a comment on ticket #1225

    For both of these equipment types 1 UI change needed: 1. PTAC's HVAC System Data under Cooling System remove 350.0 CFM/ton; CF1R/XML Changes: for both remove from HERS reporting Refrig Chg, and from HVAC Table set Refrig Chg to No. For PTHP in the HVAC table add "n/a" to 17 degree cap. and SEER.

  • Dee Anne Ross Dee Anne Ross modified ticket #1021

    Need Exterior Finish selections for Metal and Cement Fiber siding

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1226

    For both of these equipment types UI changes needed: 1. Next to EER remove "kBtuh/KW" (on HP or Cooling Sys Data screen); 2. CFM/ton remove the one on right (it is already on the left of the 350). 3. SVPHP HVAC System Data under Cooling System - data is out of order, move @47 after the COP. But it is also not updating to the COP I modeled. Order should be COP 3.5, @47Cap 36,000 Btu 12.0 EER. CF1R/XML Changes: for SPVAC remove from HERS measures reporting (p. 3) Refrig Chg. HERS Verif Table set Refrig...

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1225

    For both of these equipment types 3 UI changes needed: 1. Next to EER is kBtuh/KW (HP or Cooling Sys Data screen); 2. PTAC's HVAC System Data under Cooling System remove 350.0 CFM/ton; 3. PTHP's same screen same area - data is out of order @47 should go after the COP or COP 2.9, @47Cap 36,000 Btu 10.0 EER. CF1R/XML Changes: for both remove from HERS reporting Refrig Chg, and from HVAC Table set Refrig Chg to No. For PTHP in the HVAC table add "n/a" to 17 degree cap. and SEER.

  • Dee Anne Ross Dee Anne Ross modified ticket #1213

    PV Special Features Notes reporting

  • Dee Anne Ross Dee Anne Ross modified ticket #1195

    Ducted minisplit, multisplit

  • Dee Anne Ross Dee Anne Ross modified ticket #1235

    DHW HERS reporting for demand control types

  • Dee Anne Ross Dee Anne Ross modified ticket #1223

    19.2 Wrong IAQ W/CFM for MF Exhaust

  • Dee Anne Ross Dee Anne Ross modified ticket #1196

    PV Loophole

  • Dee Anne Ross Dee Anne Ross modified ticket #1155

    Whole House fan budgets different between traditional and vent to outside on 2700 plan

  • Dee Anne Ross Dee Anne Ross modified ticket #499

    Unable to model steel or metal floors or ceilings

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #499

    Duplicate of Ticket #706

  • Dee Anne Ross Dee Anne Ross modified ticket #356

    636 Steel Frame Ceilings and Floors don't have framing

  • Dee Anne Ross Dee Anne Ross modified ticket #828

    Support 4k UHD (ultra HD) laptop displays

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #828

    Put help in user manual and there is an old FAQ.

  • Dee Anne Ross Dee Anne Ross modified ticket #1011

    Need Heating System Type: Weatherized Gas Furances

  • Dee Anne Ross Dee Anne Ross modified ticket #1067

    Need to add new Distribution System Data Type to support VCHP and multi-split HP and AC

  • Dee Anne Ross Dee Anne Ross modified ticket #1059

    How to identify NEEA Tier 3 heat pump water heaters

  • Dee Anne Ross Dee Anne Ross modified ticket #1244

    Fixed roof mount reporting change needed

  • Dee Anne Ross Dee Anne Ross modified ticket #1151

    Duct location error

  • Dee Anne Ross Dee Anne Ross modified ticket #1062

    No Cooling duct error with mix of floor types

  • Dee Anne Ross Dee Anne Ross modified ticket #1052

    UEF water heaters in EAA & correct standard design comparison

  • Dee Anne Ross Dee Anne Ross modified ticket #1210

    Support Input of OG-300 Solar Thermal Systems

  • Dee Anne Ross Dee Anne Ross modified ticket #1237

    CF1R-PRF Reporting: Nondefault SPF R-value

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1237

    Reports on CF1R as High R-value Spray Foam Insulation. Same in field Ea01 Building Feature HERS of XML. And this matches proposed edit to ACM Ref Manual App. A.

  • Dee Anne Ross Dee Anne Ross modified ticket #1059

    How to identify NEEA Tier 3 heat pump water heaters

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1059

    Don't remember where this request originated, but the tier (and now we have Tier 4) is only part of the overall picture for which HPWH will produce better results in a given situation. Without knowing what problem this would fix, we should not fix it.

  • Dee Anne Ross Dee Anne Ross modified ticket #1209

    Update PV Inputs/Defaults/Sim to latest PVWatts

  • Dee Anne Ross Dee Anne Ross modified ticket #1067

    Need to add new Distribution System Data Type to support VCHP and multi-split HP and AC

  • Dee Anne Ross Dee Anne Ross modified ticket #1211

    Update Solar Collector (OG-100) rating data

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1211

    Work completed in another ticket.

  • Dee Anne Ross Dee Anne Ross modified ticket #1175

    WHF Penalty in Shoulder Months and Troubleshooting

  • Dee Anne Ross Dee Anne Ross modified ticket #904

    Roofing Type Naming and Roofing selections

  • Dee Anne Ross Dee Anne Ross modified ticket #1240

    ADU Fan CFM needs error check

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1241

    No, they are not the same (sorry, but I forgot I could hover and get these values). 03 is CHPWHNumComp 04 CHPWHTotTankVol (only reported when HPWHSysDescrip = Large single Pass Primary (which is not reported) 05 is CHPWHTankCount (also only for Large single Pass Primary

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1241

    Recirculation Loops possibilities are only: Conditioned Space, Semi-conditioned Space, Unconditioned Space, Underground Tank Location or Loop Tank Location (plus each has Source Air From) has two selection boxes: Outside or Zone, If Zone selection it can be a zone type of: Conditioned (or whatever user named it) Garage Attic Crawl Space Hope that is all clear.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1241

    WATER HEATERS - CHPWH table and CHPWH – LOOP TANK table should both be in the existing Tchp section: That sounds right. The loop tank is an option only for CHPWHs. It could be none, but if it is there it is a CHPWH component. RECIRCULATION LOOPS table could apply to either central DHW or CHPWH. Yes, it is a new section used with either section T WATER HEATERS or with section Tchp WATER HEATERS - CHPWH.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1187

    Posting table sent via email showing correct standard design for new, altered DHW.

  • Dee Anne Ross Dee Anne Ross modified ticket #1217

    Verified Duct Design w/o Returns

  • Dee Anne Ross Dee Anne Ross modified ticket #1215

    Incorrect Central DHW branch loss model simulated in CSE

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1215

    Since Scott posted, Scott fixed, and we apparently have no one who can verify this, I'm marking as verified.

  • Dee Anne Ross Dee Anne Ross modified ticket #1241

    XML Reporting: CHPWHs

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1241

    Attached is zip containing Word documents showing potential fixes to the schema to achieve the desired reporting for central DHW, and another for central HPWH. If you're visual they walk through of the CBECC screens to get to the desired outcome (it helped me). Another Word doc is a mock up of the CF1R. If you need, there are RIBD19 files, CF1R-BEES.XML, and CF1Rs in current form (file names are in the Word docs).

  • Dee Anne Ross Dee Anne Ross modified ticket #1208

    PV Compliance Credit to offset Standard Solar Thermal Savings

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1208

    On 8/4 Danny Tam said this is an internal calculation. There is nothing to put on the CF1R. It will be reflected in the PV size. I'm marking verified.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1242

    The attached Word document was sent around for review (had 3-4 days). OG-100 reporting needs no changes, OG-300 minor changes to add n/a to reporting. I am also attaching ribd, xml and CF1R files.

  • Dee Anne Ross Dee Anne Ross modified ticket #1056

    2019 CF1R Edits and Updates

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1056

    Despite the strategy to put the major reorganization of the CF1R in an early all-encompassing ticket, this did not work. It is too time-consuming to verify. Reorganization never happened. This ticket will be closed and any new issues will be added into more focused new ticket(s).

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1048

    Believe this is related. When there is no other option for hypothetical ducts (whether no cooling or minisplit), put them in conditioned space.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1151

    Same issue, but this is minisplit equipment. No attic. Put hypothetical ducts in conditioned space.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #904

    Limiting this to initial subject of this ticket (meaning ignore the things I added), this file has both roof types in one file, appropriately named so you can find them, Name the steep slope version of "10 PSF (RoofTile)" as "10 PSF (RoofTileAirGap)." Name "all others" version of "10 PSF (RoofTile)" as "10 PSF (RoofTileNoGap)". I will put all the other requests in a new ticket.

  • Dee Anne Ross Dee Anne Ross created ticket #1244

    Fixed roof mount reporting change needed

  • Dee Anne Ross Dee Anne Ross created ticket #1240

    ADU Fan CFM needs error check

  • Dee Anne Ross Dee Anne Ross created ticket #1239

    Inability to model Interior wall to crawlspace

  • Dee Anne Ross Dee Anne Ross created ticket #1238

    Garage Doors U-factor from JA4.5.1

  • Dee Anne Ross Dee Anne Ross modified ticket #1227

    Missing equipment: Packaged gas furnace

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1227

    And I've since noticed it is happening on others.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1229

    The only issue I find is that the ducted equipment comes in with 0 CFM. This should be 350. Please add a range check to prevent it from running (I noticed it runs with 0, reports 0, but also requires airflow testing; if 350 is entered it runs, reports 350, requires airflow. Results are the same.)

  • Dee Anne Ross Dee Anne Ross modified ticket #1195

    Ducted minisplit, multisplit

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1195

    Duplicated as Ticket #1229

  • Dee Anne Ross Dee Anne Ross modified ticket #1227

    Missing equipment: Packaged gas furnace

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1227

    I've since noticed it is happening on others ("AFUE" missing), not just new equipment types.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1227

    Only reporting issue is efficiency shows as "-81" when it should be "AFUE-81". W04_EfficiencyType>AFUE W04_EfficiencyAFUE>81 If that is a schema change, should I assign to Diane or Rob?

  • Dee Anne Ross Dee Anne Ross modified ticket #1236

    Cap needed on WHF CFM/SqFt

  • Dee Anne Ross Dee Anne Ross modified ticket #1018

    Community Solar Exception

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1227

    Attaching descriptions to use for 1 new heating system, 5 new heat pumps. A/Cs do not have a description, so I'm not adding any.

  • Dee Anne Ross Dee Anne Ross modified ticket #1194

    Interior surfaces missing from CF1R Opaque Surfaces

  • Dee Anne Ross Dee Anne Ross modified ticket #1231

    Switch Multifamily Standard Design Attics from Option B (high performance) to C

  • Dee Anne Ross Dee Anne Ross modified ticket #1214

    XML Reporting: Verified/Altered Cathedral Ceiling

  • Dee Anne Ross Dee Anne Ross modified ticket #1171

    PV Shading Multiplier

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1171

    I agree with Scott that this is the Solar Access % which is done.

  • Dee Anne Ross Dee Anne Ross modified ticket #1216

    Underground Floor reporting missing from CF1R

  • Dee Anne Ross Dee Anne Ross created ticket #1235

    DHW HERS reporting for demand control types

  • Dee Anne Ross Dee Anne Ross created ticket #1234

    Heat Pump Capacities Input and Reporting

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #904

    While you're at it, many users would like more options. Steep slope implies I can choose "wood shakes" but I can't. We should ask others (Martyn Dodd, Payam) what other words people want to see, e.g., standing seam.

  • Dee Anne Ross Dee Anne Ross modified ticket #1233

    ADU floor area and bedrooms

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1233

    Robert tells me this is already on deck for the next release.

  • Dee Anne Ross Dee Anne Ross created ticket #1233

    ADU floor area and bedrooms

  • Dee Anne Ross Dee Anne Ross modified ticket #1185

    Multifamily Central DHW count & CF1R cleanup

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1185

    You accomplished what I was seeking, so I'm verifying it. I tried to create two options for how the central systems might be modeled in hopes of catching every mess that might be created (1 system with 4 tanks, and another version had 2 systems - one with 1 tank and one with 3). Someone will likely break it, but it is doing the right thing.

  • Dee Anne Ross Dee Anne Ross created ticket #1232

    Hydronic using heat pump as heating source

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #710

    Pat Split comment 6/5/20: Residential slab-on-grade hydronic heating systems rarely use tubing installed within the structural slab anymore. The tubing is installed above the slab, either in a topping slab or some sort of panelized system. Either way, these systems have a layer of insulation completely separating the tubing from the structural slab. This cannot be modeled. The closest option is to model a 4-foot strip projecting in from the edges of the slab. This exaggerates the heat loss to the...

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1175

    From RJ: In addition to revisions to address the above issues, we'd like to add a limit to the cooling ventilation airflow of 3.5 cfm/ft2 of conditioned floor area. This is a building wide limit, so the total cooling ventilation airflow for a building can't exceed 3.5 times the total CFA of the building. • Want it to behave like IAQ (when the min IAQ airflow is not met) where an error is triggered after hitting run simulation. • We'd like there to be a UI message on the project level Cool Vent tab...

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1062

    This is another file with similar issues. I can get it to run to 39% if I switch from no cooling to minisplit, but I get a error that crawl space ducts are not valid (there are no ducts). So the hypothetical ducts are the problem.

  • Dee Anne Ross Dee Anne Ross modified ticket #1057

    Opaque Exterior Door Alterations

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1057

    Combined with #1109.

  • Dee Anne Ross Dee Anne Ross modified ticket #1187

    Altered DHW Using Wrong Standard Design

  • Dee Anne Ross Dee Anne Ross modified ticket #1057

    Opaque Exterior Door Alterations

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1057

    See ticket #1109 instead.

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1109

    Related ticket (hoping they do not conflict) includes this correction: Opaque Exterior Doors If status = existing or altered, the standard design should equal proposed so there is no credit or penalty. Opaque Exterior Door requirements are contained in 150.1(c), and there is no reference from 150.2 back to 150.1. Therefore, there is no alteration requirement for opaque exterior doors.

  • Dee Anne Ross Dee Anne Ross modified ticket #1186

    Altered HPWH crashes

  • Dee Anne Ross Dee Anne Ross posted a comment on ticket #1186

    Running in 1145 (updated this morning) has undefined data: left side of . . . errors.

  • Dee Anne Ross Dee Anne Ross modified ticket #1221

    Fenestration Average U-factor is reporting incorrect value