Activity for binil babu

  • binil babu binil babu posted a comment on discussion Help

    The Cp is of a wind turbine is maximum for a unique TSR. TSR is given by the equation TSR = (omega*R)/ U; which means at higher TSR the inlet wind velocity is slow. That may be the reason for negative Cp.

  • binil babu binil babu posted a comment on discussion Help

    The Cp of a wind turbine is maximum for a unique TSR.

  • binil babu binil babu posted a comment on discussion Bug Reports

    how to ink the libstdc++.so.6 to that as (from the bin directory of qblade): ln -sf /usr/lib/x86_64-linux-gnu/libstdc++.so.6.0 libstdc++.so.6? please suggest!

1