#1913 fix a potential double free

Stability
pending-remind
sfcb (1090)
5
2011-06-10
2010-03-30
John Powell
No

In some error condition, the control message is double-free.

Discussion

  • John Powell

    John Powell - 2010-03-30
     
  • Chris Buccella

    Chris Buccella - 2010-04-07

    Looks like this patch is dependent on another patch ("receiver" does not exist in the current codebase).

     
  • Chris Buccella

    Chris Buccella - 2011-06-10
    • status: open --> pending-remind
     
  • Chris Buccella

    Chris Buccella - 2011-06-10

    Attached patch won't apply; patch file needs to be in unified format
    (containing context).

    Set to Pending while awaiting update. SF will close this in 60 days.

     