Fixed
- A connection attempt that outlives its timeout no longer terminates the pool,
and with it every caller of that pool. The dial is made with the request's
connect_timeout, and a call that times out, like a connection process that dies while dialing, comes back as a checkout error (#927, [#928], thanks @aboroska). - Handing a pooled connection to a new owner, and the prewarm dial, are guarded like the other calls the pool makes into a connection process. A connection that is gone or wedged is dropped instead of taking the pool down (#929).
- Stopping a connection from inside the pool is bounded to 100ms, after which the connection is killed. A connection wedged in a transport call, which a failed dial makes likely, used to hold every caller of the pool for as long as the transport took to return (#929).
- The health probes the pool runs on a connection (
is_ready,checkin_info,set_owner,get_state) take an explicit timeout, and the pool passes 250ms.h2_conn_usable/1used the 5s default, so one wedged HTTP/2 connection stalled the pool for 5 seconds on every checkout for that host (#929).
Added
- Fault injection test harness for the pool: a transport which can be told to
misbehave, a sentinel which makes a dead pool visible, fault and chaos
suites, and a structural test which fails if the pool calls a connection
process outside a
try.DEVELOPMENT.mdexplains how to use it (#929).
Changed
- Update dependencies to their latest releases:
h20.12.0 andwebtransport0.4.5 (#930).