Download Latest Version Example01.acs (57.3 MB)
Email in envelope

Get an email when there's a new version of Flow Cytometry Data Standards

Home / OldFiles
Name Modified Size InfoDownloads / Week
Parent folder
FCS31_Normative_20081027.pdf 2008-10-28 112.4 kB
ComplianceTests_FAQs_and_Issues_20081007.zip 2008-10-07 5.6 MB
Gating-ML.v1.5.081007.pdf 2008-10-07 1.8 MB
Gating-ML.v1.5.081007.Compliance-tests.081007.zip 2008-10-07 2.1 MB
Gating-ML.v1.5.081007.full.zip 2008-10-07 2.9 MB
ComplianceTests_FAQs_and_Issues_20081003.zip 2008-10-03 5.6 MB
Gating-ML.v1.5.080311.Compliance-tests.080902.zip 2008-09-03 4.0 MB
Gating-ML.v1.5.080311.Compliance-tests.0804.zip 2008-04-05 2.2 MB
Usage.example.acz 2008-03-25 1.2 MB
Extension.example.zip 2008-03-25 2.9 kB
Gating-ML.v1.5.080311.full.zip 2008-03-11 3.1 MB
Gating-ML.v1.5.080311.pdf 2008-03-11 2.2 MB
Gating-ML.v1.5.080120.full.zip 2008-01-20 2.9 MB
Gating-ML.v1.5.080120.pdf 2008-01-20 1.8 MB
Gating-ML.v1.5.071220.full.zip 2007-12-20 3.7 MB
Gating-ML.v1.5.071220.pdf 2007-12-20 2.4 MB
Conventions_071220.pdf 2007-12-20 89.6 kB
Gating-ML.v1.5.071217.full.zip 2007-12-18 3.7 MB
Gating-ML.v1.5.071217.pdf 2007-12-18 2.4 MB
Rationale_for_transformations_in_Gating-ML.pdf 2007-12-12 107.0 kB
Gating-ML.v1.5.071205.full.zip 2007-12-05 3.7 MB
Gating-ML.v1.5.071205.pdf 2007-12-05 2.3 MB
Gating-ML.v1.5.071126.full.zip 2007-11-26 3.7 MB
Gating-ML.v1.5.071126.pdf 2007-11-26 2.3 MB
Gating-ML.v1.5.071115.full.zip 2007-11-15 3.5 MB
Gating-ML.v1.5.071115.pdf 2007-11-15 1.8 MB
MIFlowCyt.v071101.pdf 2007-11-01 275.3 kB
MIFlowCyt_v071101.pdf 2007-11-01 275.3 kB
MIFlowCyt_v070917.pdf 2007-11-01 64.6 kB
Conventions_071011.pdf 2007-10-11 84.9 kB
Conventions071011.pdf 2007-10-11 85.0 kB
Reqv0.2.zip 2007-07-26 85.7 kB
Compensation-ML.v1.1.01.zip 2007-07-20 882.0 kB
Gating-ML.v1.3.pdf 2007-07-12 748.8 kB
Gating-ML.v1.3.zip 2007-07-12 3.5 MB
FlowRDF.v1.1.pdf 2007-07-12 517.4 kB
Reqv0.1.zip 2007-07-12 130.2 kB
Transformation-ML.v1.2.zip 2007-07-12 3.9 MB
Transformation-ML.v1.2.pdf 2007-07-12 843.3 kB
Compensation-ML.v1.1.pdf 2007-07-12 333.7 kB
Compensation-ML.v1.1.zip 2007-07-12 880.9 kB
MIFlowCyt_normative_standard_proposal_v070525.pdf 2007-05-30 92.6 kB
MIFlowCyt_normative_standard_proposal_v070526.pdf 2007-05-30 92.6 kB
Gating-ML.distribution.v1.2.zip 2007-05-17 3.1 MB
MIFlowCyt_v.0.5.04.pdf 2007-05-10 59.5 kB
MIFlowCyt_v.0.4.13.pdf 2007-04-16 272.3 kB
Gating-ML_v1.1.04_test_files.zip 2007-03-30 1.5 MB
Gating-ML_v1.1.03_test_files.zip 2007-03-06 718.7 kB
acscsv.1.0.1.bin.win32.i386.zip 2007-03-06 682.0 kB
Gating-ML_v1.1.02_test_files.zip 2007-03-05 494.8 kB
acscsv.1.0.0.bin.RedHatLinux.i386.zip 2007-03-04 661.5 kB
acscsv.1.0.0.src.zip 2007-03-04 713.9 kB
acscsv.1.0.0.bin.win32.i386.zip 2007-03-04 672.4 kB
ACS1_rationale_for_changes.pdf 2007-02-13 133.9 kB
ASC1_v0.8.pdf 2007-02-13 127.5 kB
MIFlowCyt_v.0.3.13.pdf 2007-02-08 40.2 kB
Gating-ML_v1.1_test_files.zip 2007-02-06 494.7 kB
Transformation-ML_v1.0_test_files.zip 2007-02-06 26.2 kB
Compensation-ML_v1.0_test_files.zip 2007-02-06 23.9 kB
Rationale_for_changes_to_FCS3.0.pdf 2007-02-02 283.1 kB
Rationale_for_changes_to_FCS3.pdf 2007-02-02 133.3 kB
MIFlowCyt-README.txt 2007-01-22 1.5 kB
Transformation-ML_v1.0.zip 2006-12-12 9.9 MB
Compensation-ML_v1.0.zip 2006-12-12 375.4 kB
Gating-ML_v1.1.zip 2006-12-12 720.1 kB
Transformation-ML_v1.0.pdf 2006-12-12 406.3 kB
Gating-ML_v1.1.pdf 2006-12-12 443.4 kB
Compensation-ML_v1.0.pdf 2006-12-12 262.8 kB
Transformation-ML.v1.0.26.pdf 2006-12-12 406.3 kB
Gating-ML.v1.1.26.pdf 2006-12-12 443.4 kB
Compensation-ML.v1.0.24.pdf 2006-12-12 262.8 kB
Proposa_for_FCS4.pdf 2006-12-11 282.0 kB
Proposal_for_FCS4.0.pdf 2006-11-14 282.5 kB
Proposal_for_FCS4.pdf 2006-11-14 282.4 kB
FCSmixture.zip 2006-11-14 1.5 MB
facejava-1.0B1-uml.zip 2006-09-22 4.4 MB
MIFACE.v.1.1.pdf 2006-09-19 200.7 kB
MIFACE_worksheet.v.1.1.xls 2006-09-19 59.9 kB
Proposal_for_FCS_4.0.pdf 2006-09-15 279.0 kB
Proposal_for_FCS_4.pdf 2006-09-15 269.6 kB
flip_byte_order_performance_test.zip 2006-09-02 2.5 kB
wtr.pdf 2006-09-01 3.6 MB
FcmMDR.v.1.0.rdfs 2006-08-31 5.3 kB
FlowRDF.v1.0.pdf 2006-08-31 654.7 kB
FlowFuGEm3v01.zip 2006-08-31 573.9 kB
FlowFuGE.readme.txt 2006-08-31 2.0 kB
RFlowCyt.readme.txt 2006-08-30 285 Bytes
FACEOntology.readme.txt 2006-08-30 184 Bytes
FACEOntology.download.url 2006-08-30 83 Bytes
FACEOntology-FuGO.download.url 2006-08-30 83 Bytes
readme.FACEOntology.txt 2006-08-30 184 Bytes
FACEOntology-FuGO.download.url.url 2006-08-30 83 Bytes
readme.txt 2006-08-30 285 Bytes
RFlowCyt.download.url 2006-08-30 79 Bytes
MIFACE_worksheet.v.1.0.xls 2006-08-30 58.9 kB
MIFACE.v.1.0.pdf 2006-08-30 69.5 kB
rflowcyt_1.4.0.tar.gz 2006-08-30 2.2 MB
rflowcyt_1.4.0.zip 2006-08-30 2.8 MB
rflowcyt_1.4.0.gz 2006-08-30 2.5 MB
rflowcyt.pdf 2006-08-30 11.6 MB
Transformation-ML.v1.0.pdf 2006-08-30 406.7 kB
Gating-ML.v1.1.pdf 2006-08-30 443.3 kB
Compensation-ML.v1.0.pdf 2006-08-30 262.7 kB
Transformation-ML.v1.0.zip 2006-08-30 9.9 MB
Compensation-ML.v1.0.zip 2006-08-30 375.3 kB
Gating-ML.v1.1.zip 2006-08-30 720.0 kB
Totals: 106 Items   145.1 MB 1
MIFlowCyt
*********

Minimum Information for a Flow Cytometry Experiment

A standard for outlining the minimum information required to unambiguously record the experimental details of flow cytometry experiments.

MIFlowCyt development is open to wide community collaboration. Please follow the link: 

  http://wiki.ficcs.org/ficcs/MIFlowCyt

to download the latest proposal or and/or to provide your comments on the proposal.


Abstract:
*********
Flow cytometry is an analytical technique used in basic and clinical research for studying the immunological status of patients treated with vaccines or other immunotherapies, for characterizing cancer, HIV/AIDS infection and other diseases, as well as for research and therapy involving stem cell manipulation and several other applications. The fundamental tenet of any scientific research is that the published results of any study have to be open to independent validation or refutation. The purpose of this document is to establish criteria to record flow cytometry experiments in a way that provides enough detail to allow for correct third-party understanding without having to make baseless assumptions and guesses regarding any part of the experiment, analysis, and results. It promotes consistent annotation of biological and technical issues surrounding a flow cytometry experiment by specifying the requirements for data content and providing a structured framework for capturing information.
Source: MIFlowCyt-README.txt, updated 2007-01-22