Name | Modified | Size | Downloads / Week |
---|---|---|---|
readme.txt | 2018-02-16 | 2.6 kB | |
BrightCore BACnet Lookout V2.7.x User Guide.pdf | 2016-03-15 | 5.0 MB | |
Totals: 2 Items | 5.0 MB | 0 |
As of version 2.8.3 BACnet Lookout will no longer be available as download link from SourceForge.net For any info please contat us at www.BrightCore.biz Version 2.8.3.6 - BACnet Standard 135-2016 - Revision 19 Changes When Creating Remote Device, the Device Instance Tree node will now again show proper Device Instance if "I Don't know Device Instance" option was selected in the Create Remote Device window. Fixed some issues that could cause the application to crash if Object and Property didn't exist when reporting Errors in System Messages Window. BACnet Reject and Abort services will now report to the Read Property Display window if they occur. Version 2.8.3.5 - BACnet Standard 135-2016 - REV1.19 Changes Updated all internal property lists to BACnet Standard 135-2016 - Revision 19 Fixed the issue where reading display window showed internal property list instead of Object's Property List Reading Access Rule Object can now be read with ReadProperty Service instead only with ReadPropertyMultiple Service Member_Of, Belongs_To, Zone_From, Zone_To, Last_Credential_Added and Last_Credential_Removed properties will now be decoded as Device-Object-Reference. Version 2.8.3.4 - BACnet Standard 135-2012 - REV1.14 Fixed the issue where reading properties through Property_List property failed after the first object was read. Version 2.8.3.2 - BACnet Standard 135-2012 - REV1.14 Fixed the issue where Lookout didn't restart on changed settings. Version 2.8.3 - BACnet Standard 135-2012 - REV1.14 Implemented a new version of reading Objects and Properties. This will spead up the reading when accessing IP remote device and will be faster and completly reliable when reading MSTP devices. Version 2.8.2 - BACnet Standard 135-2012 - REV1.14 CHANGES Foreign Device services will now correctly display failure or success. If Property List property is not found but Protocol Revision property specifies that it should, Lookout will now display an error message in the Message Log if it encounters this situations. If accessed from the Context Menu, WhoIs dialog will now show the select device's address by default. Enable/Disable Notification Listener will now correctly save/load. Input schedul window will not longer close when enter is pressed. Fixed an issue where Lookout would use 50% of processor time when using MSTP. Fixed the Setup issue where required folder would not be created during setup on Extended version of BACnet Lookout.