From: Sander A. <sa....@fz...> - 2020-07-20 12:34:28
|
Hi Krzysztof, we discussed it internally and having the possibility to configure an return/forward URL would be the best in our opinion. We could send the users to a specific page where they get further information or could request access to the service. Best regards, Sander On Mon, 2020-07-20 at 12:25 +0200, Krzysztof Benedyczak wrote: > Hi, > > W dniu 17.07.2020 o 08:28, Sander Apweiler pisze: > > Good morning Krzysztof, > > we tested the fail Authentication action in the translation > > profiles to > > do a lightweight ABAC/authorisation within unity for service who > > can't > > do it by itself. > > We encountered some problems/not optimal behaviour in it. The error > > message is only send to service, but not to the users. The services > > can > > not handle such specific error messages and the user get a very > > strange > > error at the service. E.g. the error of Nextcloud is: > > "Account not provisioned. > > Your account is not provisioned, access to this service is thus not > > possible." > > > > The user do not really understand why the login fails. From our > > point > > of view it would be great if the failed authentication error is > > shown > > to the user, maybe with the possibility to login with another > > account. > > Do you see a possibility to extend the fail authentication > > behaviour? > > Yes, we can extend this action. Adding a checkbox: "show error > internally" + its implementation is easy. However, is it going to be > useful? Just to stop the user on unity error page? Shall we redirect > back to the service (so the error, perhaps wrong if the service > doesn't > implement error handling correctly, will be shown again)? Or redirect > to > other address (like article in help center)? > > Best, > KB > -- Federated Systems and Data Juelich Supercomputing Centre phone: +49 2461 61 8847 fax: +49 2461 61 6656 email: sa....@fz... ---------------------------------------------------------------------- ----------------------------------------------------------------------- Forschungszentrum Juelich GmbH 52425 Juelich Sitz der Gesellschaft: Juelich Eingetragen im Handelsregister des Amtsgerichts Dueren Nr. HR B 3498 Vorsitzender des Aufsichtsrats: MinDir Volker Rieke Geschaeftsfuehrung: Prof. Dr.-Ing. Wolfgang Marquardt (Vorsitzender), Karsten Beneke (stellv. Vorsitzender), Prof. Dr.-Ing. Harald Bolt ----------------------------------------------------------------------- ----------------------------------------------------------------------- |