From: Sander A. <sa....@fz...> - 2018-11-15 13:31:22
|
Hi Krzysztof, at the moment I'm testing unity 2.7.2. I have enabled different kind of authenticators, one of the are local accounts with username password. I have enabled the user registration on userhome too (see userhome.properties config below), but the link "Register a new account" from previous versions is not available on the userhome. Is this behaviour intended? unity.userhome.attributes.1.attribute=cn unity.userhome.attributes.1.group=/ unity.userhome.attributes.1.showGroup=false unity.userhome.attributes.1.editable=true unity.userhome.attributes.2.attribute=mail unity.userhome.attributes.2.group=/ unity.userhome.attributes.2.showGroup=false unity.userhome.attributes.2.editable=true unity.userhome.attributes.3.attribute=o unity.userhome.attributes.3.group=/ unity.userhome.attributes.3.showGroup=false unity.user10home.attributes.3.editable=true unity.userhome.attributes.4.attribute=picture unity.userhome.attributes.4.group=/ unity.userhome.attributes.4.showGroup=false unity.userhome.attributes.4.editable=true unity.endpoint.web.enableRegistration=true unity.endpoint.web.authnScreenOptionsLabel.OR.text=OR unity.endpoint.web.authnGrid.G1.gridContents=samlWeb unity.endpoint.web.authnGrid.G1.gridRows=10 unity.endpoint.web.authnScreenColumn.1.columnSeparator=OR unity.endpoint.web.authnScreenColumn.1.columnWidth=17 unity.endpoint.web.authnScreenColumn.1.columnContents=pwdWeb unity.endpoint.web.authnScreenColumn.2.columnSeparator=OR unity.endpoint.web.authnScreenColumn.2.columnWidth=34 unity.endpoint.web.authnScreenColumn.2.columnContents=_GRID_G1 unity.endpoint.web.authnScreenColumn.3.columnSeparator=OR unity.endpoint.web.authnScreenColumn.3.columnWidth=17 unity.endpoint.web.authnScreenColumn.3.columnContents=oauthWeb Best regards, Sander -- Federated Systems and Data Juelich Supercomputing Centre phone: +49 2461 61 8847 fax: +49 2461 61 6656 email: sa....@fz... ---------------------------------------------------------------------- ----------------------------------------------------------------------- Forschungszentrum Juelich GmbH 52425 Juelich Sitz der Gesellschaft: Juelich Eingetragen im Handelsregister des Amtsgerichts Dueren Nr. HR B 3498 Vorsitzender des Aufsichtsrats: MinDir Dr. Karl Eugen Huthmacher Geschaeftsfuehrung: Prof. Dr.-Ing. Wolfgang Marquardt (Vorsitzender), Karsten Beneke (stellv. Vorsitzender), Prof. Dr.-Ing. Harald Bolt, Prof. Dr. Sebastian M. Schmidt ----------------------------------------------------------------------- ----------------------------------------------------------------------- |