#9 Stopbits setting over telnet rfc2217

closed-fixed
nobody
None
5
2005-10-20
2005-10-20
Anonymous
No

When setting stopbits over telnet ala rfc 2217 ser2net
accepts only 1 and 3 as setting. But in rcf 2217 it
says that 1=1sb, 2=2 sb and 3=1.5. I see in the comment
that 1.5 isn't supported so this isn't the intended
behaviour?

Best regards,
Hans

Discussion

  • Corey Minyard

    Corey Minyard - 2005-10-20
    • status: open --> closed-fixed
     
  • Corey Minyard

    Corey Minyard - 2005-10-20

    Logged In: YES
    user_id=236278

    You are correct, fix is in CVS and will be out in the next
    release. Thanks.

     
  • H C

    H C - 2005-10-21

    Logged In: YES
    user_id=1365103

    Great. Fast response and a good job (for it all)!

    Hans

     