#77 Transformers not modeled right for DC

closed-fixed
None
5
2011-03-06
2011-03-03
Rob Frohne
No

>. I noticed that with
> simultaneous S parameter and DC simulations using a transformer doesn't
> seem to get the DC analysis right. (The transformer seems to act as a
> resistor of high impedance at DC.)

Rob

Discussion

  • Stefan Jahn

    Stefan Jahn - 2011-03-06

    The bug has been fixed in SVN. Thanks a lot for reporting it.

     
  • Stefan Jahn

    Stefan Jahn - 2011-03-06
    • assigned_to: nobody --> ela
    • status: open --> closed-fixed
     