#17 Warning and crash when cancelling object creation

closed-fixed
nobody
5
2012-12-05
2010-02-08
No

When I do the following steps:
- select "create new object file", select a file name to extract, subtract bias, perform wavelength calib, "OK",
- in the "Set New Data variable" dialog box, hit "Cancel" without selecting anything else

I get a warning message ""The following error was encountered: Subscript range values of the form low:high must be >= 0, < size, with low <= high: <No name>. Please consult the supplier of the application.," and an OK button. Pressing "OK" here crashes p3d with a segfault.

No debug output.

Discussion

  • Ole Streicher

    Ole Streicher - 2010-02-08

    Additional comment: an output file was created, even if this was not my intention -- the reason to press "Cancel" was that I recognized that I used the wrong output directory.

     
  • Ole Streicher

    Ole Streicher - 2010-02-08
    • summary: Warning when cancelling object creation --> Warning and crash when cancelling object creation
     
  • Christer Sandin

    Christer Sandin - 2012-12-05
    • status: open --> closed-fixed
     
  • Christer Sandin

    Christer Sandin - 2012-12-05

    Fixed (earlier).

     

Get latest updates about Open Source Projects, Conferences and News.

Sign up for the SourceForge newsletter:





No, thanks