Printed Spire labs not displaying Abn column values correctly
open source web-based Electronic Medical Record (EMR) system
Brought to you by:
davidhcchan,
jaygallagher
Replicated in R12_1 build # 516. Attached pdf file.
Downgrading priority to 7 (high) according to the bug classification list.
Diff:
Hi Suni,
We disagree with the adjustment to the severity rating of the ticket. Firstly, there is no workaround available for this issue. Secondly, if the lab was attached to a consult and printed or faxed, the formatting issues will show an incorrect value as to whether or not the lab is abnormal or not. This can negatively affect patient safety.
Please re-review.
per my Email earlier.
Fixed.
commit: https://source.oscartools.org:8080/12544
For some reason the Oscar Handler for Spire labs assumes Abn values to be words like "CRIT" and "ABN", which is unlike any other labs and not mentioned in Hl7 documentations.
Diff:
Re-tested R12_1 build # 535 -> issue has been resolved. Attahched print pdf file.
Not applicable to Master.
Last edit: SBek 2015-08-18