ecospold 1 export from openLCA doesn't export the field value for "Infrastructure Process". No matter if you tick the field "Infrastructure process" in a process' "General Information" tab, the exported ecospold file will always contain the field:
<dataset>
<metaInformation>
<processInformation>
<referenceFunction infrastructureProcess="false"
and the same problem exists also for included exchange processes:
<flowData>
<exchange infrastructureProcess="false" >
The same applies to datasets exported with the ILCD exporter and then converted to ecospold 1 using the stand-alone converter tool.
We are using openLCA version 1.3.4
should be fixed with version 1.4.1 (beta7)