NetToPLCSim Wiki
Brought to you by:
thomas_v2
Especially for the S7-1200/S7-1500 controllers, there are incompabilities due to the authentication mechanisms of these controllers.
As the PLCSIM versions are using different keys, not all client software versions are able to establish a connection to PLCSIM. As NetToPLCSim acts as a bridge to the underlying S7ONLINE interface, this is not something that can be fixed inside NetToPLCSim.
This does not concern the Put/Get communication with absolute addresses.
The following table gives some combinations which were tested with NetToPLCSim V1.2.4:
Client-Software | TIA Version | Result |
---|---|---|
WinCC 7.2 | Info: WinCC 7.2 only supports "not optimized" datablocks | |
WinCC 7.2 (7.2.0.11) | TIA V15.1 Plcsim (Upd3) | |
WinCC 7.2 (7.2.0.15) | TIA V15.1 Plcsim (Upd3) | |
WinCC 7.2 (7.2.0.11) | TIA V14 Plcsim (SP1+Upd7) | |
WinCC 7.2 (7.2.0.11) | TIA V13 Plcsim (SP1+Upd6) | |
WinCC 7.3 | ||
WinCC 7.3 (7.3.0.0) | TIA V15.1 Plcsim (Upd3) | |
WinCC 7.3 (7.3.0.0) | TIA V14 Plcsim (SP1+Upd7) | |
WinCC 7.3 (7.3.0.0) | TIA V13 Plcsim (SP1+Upd6) | |
WinCC 7.4 | ||
WinCC 7.4 (7.4.1.13) | TIA V15.1 Plcsim (Upd3) | |
WinCC 7.4 (7.4.1.13) | TIA V15 Plcsim (Upd4) | |
WinCC 7.4 (7.4.1.13) | TIA V14 Plcsim (SP1+Upd7) | |
WinCC 7.4 (7.4.1.13) | TIA V13 Plcsim (SP1+Upd6) | |
Simatic.Net V12.0 OPC Server | Info: Comes with WinCC 7.3 | |
Simatic.Net V12.0 SP2 OPC | TIA V14 Plcsim (SP1+Upd1) | |
Simatic.Net V12.0 SP2 OPC | TIA V13 Plcsim (SP1+Upd4) | |
Simatic.Net V14.0 OPC Server | Info: Comes with WinCC 7.4 | |
Simatic.Net V14.0 OPC | TIA V14 Plcsim (SP1+Upd1) | |
Simatic.Net V14.0 OPC | TIA V13 Plcsim (SP1+Upd4) | |
Simatic.Net V15.0 OPC Server | Info: Comes with WinCC 7.5 (SP2) | |
Simatic.Net V15.0 OPC | TIA V16 Plcsim (Upd6) | |
Simatic.Net V18.0 OPC Server | ||
Simatic.Net V18.0 OPC | TIA V16 Plcsim (Upd6) |