ATI-MIB DEFINITIONS ::= BEGIN

-- Combination of this MIB :
   -- Title:    Allied Telesis Inc. MIB
   -- Date:     April 4, 1991
   -- By:       Keith Franklin/ATI
   -- Edited    Version 4.1 Firmware
-- And this one :
    --   AThub-mib
    --   Release 4.0
    --   Supported by AT-S4 rev 3.2, AT-S5 rev 3.2, and AT-S10 rev 4.0

-- put together by hand by max baker. Damn them for recycling mib names
--      11/1/04

IMPORTS
        enterprises, OBJECT-TYPE, NetworkAddress, IpAddress,
        Counter, Gauge, TimeTicks, mib-2
               FROM SNMPv2-SMI
         DisplayString
               FROM RFC1213-MIB
         TRAP-TYPE
               FROM RFC-1215
         rptrAddrTrackNewLastSrcAddress
               FROM RFC1516-MIB;

  --
  --  General Definitions
  --

   MacAddress ::= OCTET STRING (SIZE (6))    -- a 6 octet address

  --
  -- Enterprise specific
  --

   alliedTelesyn OBJECT IDENTIFIER ::= { enterprises 207 }

   products OBJECT IDENTIFIER      ::= { alliedTelesyn 1 }

   bridge OBJECT IDENTIFIER        ::= { products 1 }
   repeater OBJECT IDENTIFIER      ::= { products 2 }

   atiBridgeagent      OBJECT IDENTIFIER ::= { bridge 1 }


   bridgesnmpd          OBJECT IDENTIFIER ::= { atiBridgeagent 1 }

   atiBridge        OBJECT IDENTIFIER ::= { bridgesnmpd 1 }

   filterTable          OBJECT IDENTIFIER ::= { alliedTelesyn 2 }

   spanningTree       OBJECT IDENTIFIER ::= { alliedTelesyn 6 }

   mibObject OBJECT IDENTIFIER     ::= { alliedTelesyn 8 }
   atiTrapAttrs OBJECT IDENTIFIER  ::= { alliedTelesyn 9 }

--- hub mib
   hub3600 OBJECT IDENTIFIER       ::= { repeater 1 }
   hub3100 OBJECT IDENTIFIER       ::= { repeater 10 }
   hubTurboStack OBJECT IDENTIFIER ::= { repeater 65 }

   hubMib OBJECT IDENTIFIER        ::= { mibObject 1 }

   rptrInfo OBJECT IDENTIFIER      ::= { hubMib 1 }
   groupInfo OBJECT IDENTIFIER     ::= { hubMib 2 }
   portInfo OBJECT IDENTIFIER      ::= { hubMib 3 }
   rptrStat OBJECT IDENTIFIER      ::= { hubMib 4 }
   groupStat OBJECT IDENTIFIER     ::= { hubMib 5 }
   groupSAT OBJECT IDENTIFIER      ::= { hubMib 6 }
 
  --
  -- Following are configuration parameters for the entire managed repeater.
  --

   actualIPAddr OBJECT-TYPE
       SYNTAX IpAddress
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION  "The actual IP Address that is currently being used by the
             hub. This could be the same value as hubIPAddr, or it may
             be different if another IP Address was received via Bootp."
       ::= { rptrInfo 1 }

   hubIPAddr OBJECT-TYPE
       SYNTAX IpAddress
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION  "The configured IP Address of the hub."
       ::= { rptrInfo 2 }

   subnetMask OBJECT-TYPE
       SYNTAX IpAddress
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION  "Subnet mask of the hub."
       ::= { rptrInfo 3 }

   routerAddr OBJECT-TYPE
       SYNTAX IpAddress
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION  "Gateway/router address of the hub."
       ::= { rptrInfo 4 }

  snmpManager OBJECT-TYPE
       SYNTAX IpAddress
       ACCESS read-write
       STATUS deprecated
       DESCRIPTION  "IP Address of the hub's SNMP manager to which Traps
             will be sent."
       ::= { rptrInfo 5 }
 
   softwareProduct OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..255))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION  "The ATI software product model number running in the hub."
      ::= { rptrInfo 6 }

   softwareLevel OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..255))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION  "The software release level running in the hub."
       ::= { rptrInfo 7 }

   configurationChanged  OBJECT-TYPE
       SYNTAX  INTEGER {
             changed(1),
             nochange(2)
         }
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION  "A flag, set to the value changed(1) when any of the
             hub's status or configuration has been changed.
             When this object is read, then the value is reset
             to nochange(2)."
       ::= { rptrInfo 8 }


       rptrNmMgrTable   OBJECT-TYPE
            SYNTAX  SEQUENCE OF RptrNmMgrEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "
                A list of SNMP Trap Manager stations Entries.
                The number of entries is given by the
                rptrNmMgrTotal mib object.
                "
            ::= { rptrInfo 9 }
 
      rptrNmMgrEntry OBJECT-TYPE
            SYNTAX  RptrNmMgrEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "
                An Trap receipt Manager Entry containing ipaddress of 
                the configured NMS's to which Traps are sent.
                "
            INDEX { rptrNmMgrIndex }
            ::= { rptrNmMgrTable 1 }
 
     RptrNmMgrEntry ::=
            SEQUENCE {
                    rptrNmMgrIndex  INTEGER,
                    rptrNmMgrIpAddr IpAddress
            }
 
    rptrNmMgrIndex OBJECT-TYPE
            SYNTAX  INTEGER(1..4)
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "
                The Index of SNMP Managers IP Address.
                "
            ::= { rptrNmMgrEntry 1 }

    rptrNmMgrIpAddr OBJECT-TYPE
            SYNTAX  IpAddress
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "
                The IP Address of the NMS host configured.
                "
            ::= { rptrNmMgrEntry 2 }

--
-- Following is table for all devices in the chassis.
--

    deviceTable OBJECT-TYPE
        SYNTAX  SEQUENCE OF DeviceEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
        "The table contains the mapping of all devices
         in the chassis. For all hubs and switches, the
         object 'deviceQuadrant' returns 'right' (1).
         For docking devices, then it will reflect the 
         position of the device in the docking station.
         This object is specific to Turbo Stack.
        "
        ::= { rptrInfo  10}
 
    deviceEntry OBJECT-TYPE
        SYNTAX  DeviceEntry
        ACCESS  not-accessible
        STATUS  mandatory
        DESCRIPTION
        "The device entry in the DeviceTable. 
        "
        INDEX { deviceIndex, deviceQuadrant }
        ::= { deviceTable 1 }
 
     DeviceEntry ::=
        SEQUENCE {
            deviceIndex     
            INTEGER,
            deviceQuadrant          
            INTEGER,
            deviceDescr
            DisplayString,
            deviceObjectID
            OBJECT IDENTIFIER,
            deviceIpAddr    
            IpAddress,
            devicePortCapacity
            INTEGER
            }

    deviceIndex  OBJECT-TYPE
        SYNTAX    INTEGER(1..8)
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION 
        "
          The Slot number in the chassis where the device is 
          installed.
        "
    ::=  { deviceEntry 1 }

    
    deviceQuadrant  OBJECT-TYPE
        SYNTAX    INTEGER {
            right(1),
            left(2)
            }
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION 
        "The Quadrant of the device.
        "
    ::=  { deviceEntry 2 }

      
    deviceDescr     OBJECT-TYPE
        SYNTAX    DisplayString (SIZE (0..255))
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
        "TurboStack product family only.
         A textual description of the device.
         For devices that are repeaters, this value is identical to
        the rptrGroupDescr object.
        "
    ::=  { deviceEntry 3 }
    

    deviceObjectID OBJECT-TYPE
        SYNTAX    OBJECT IDENTIFIER
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
        "TurboStack product family only.
         The sysObject identification of the device.
         For devices that are repeaters, this value is identical to
         the rptrGroupObjectID object.
        "
       ::= { deviceEntry 4 }

    deviceIpAddr OBJECT-TYPE
        SYNTAX    IpAddress
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
        "TurboStack product family only.
         The IP address (if present) of the device.
         For hubs devices, this object will return the same
         value as hubIPAddr.
        "
       ::= { deviceEntry 5 }

   devicePortCapacity OBJECT-TYPE
        SYNTAX    INTEGER (1..1024)
        ACCESS    read-only
        STATUS    mandatory
        DESCRIPTION
        "TurboStack product family only.
         The number of ports contained within the device.
         Valid range is 1-1024.  Within each device, the
         ports are uniquely numbered in the range from
         1 to devicePortCapacity.
         For devices that are repeaters, this value is identical to
         the rptrGroupPortCapacity object."
       ::= { deviceEntry 6}

   localOmegaState    OBJECT-TYPE
        SYNTAX    INTEGER {
            enabled(1),
            disabled(2)
            }
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION 
        "
         This object enables the Local Omega to be enabled or disabled.
        "
    ::=  { rptrInfo 11 }

   remoteOmegaState    OBJECT-TYPE
        SYNTAX    INTEGER {
            enabled(1),
            disabled(2)
            }
        ACCESS    read-write
        STATUS    mandatory
        DESCRIPTION 
        "
         This object enables the Remote Omega to be enabled or disabled.
        "
    ::=  { rptrInfo 12 }

--
-- Following are statistics collected for the entire repeater.
--

  hubReadableFrames  OBJECT-TYPE
       SYNTAX    Counter
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION  "The sum total of the Readable Frames Counters
             of all ports on all modules/groups"
       ::= { rptrStat 1 }

  hubReadableOctets  OBJECT-TYPE
       SYNTAX    Counter
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION  "The sum total of the Readable Octets (bytes) Counters
             of all ports on all modules/groups"
       ::= { rptrStat 2 }

  hubFCSError  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the FCS (CRC) Error Counters of all
             ports on all modules/groups"
      ::= { rptrStat 3 }

  hubAlignError  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Alignment Error Counters of all
             ports on all modules/groups"
      ::= { rptrStat 4 }

  hubFrameTooLong  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Frame Too Long Error Counters of all
             ports on all modules/groups"
      ::= { rptrStat 5 }

  hubShortEvent  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Short Event Error Counters of all
             ports on all modules/groups"
      ::= { rptrStat 6 }

  hubRunt  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Runt Error Counters of all
             ports on all modules/groups"
      ::= { rptrStat 7 }

  hubLateEvent  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Late Event Error Counters of all
             ports on all modules/groups"
      ::= { rptrStat 8 }

  hubVeryLongEvent  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Very Long Event Error (Jabber)
             Counters of all ports on all modules/groups"
      ::= { rptrStat 9 }

  hubDataRateMism  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Data Rate Mismatch Error Counters
             of all ports on all modules/groups"
      ::= { rptrStat 10 }

  hubAutoPartition  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Auto Port Partition Counters
             of all ports on all modules/groups"
      ::= { rptrStat 11 }

  hubTotalError  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of all Error Counters
             of all ports on all modules/groups"
      ::= { rptrStat 12 }

  hubPortCollision  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Port Collision Counters
             of all ports on all modules/groups"
      ::= { rptrStat 13 }


  hubFrames-64-127bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on all modules/groups, where
        the frame length was in the range 64 through 127 octets."
       ::= { rptrStat 14 }

  hubFrames-128-255bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on all modules/groups, where
        the frame length was in the range 128 through 255 octets."
       ::= { rptrStat 15 }

  hubFrames-256-511bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on all modules/groups, where
        the frame length was in the range 256 through 511 octets."
       ::= { rptrStat 16 }

  hubFrames-512-1023bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on all modules/groups, where
        the frame length was in the range 512 through 1023 octets."
       ::= { rptrStat 17 }

  hubFrames-1024-1518bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on all modules/groups, where
        the frame length was in the range 1024 through 1518 octets."
       ::= { rptrStat 18 }

   ledInfo  OBJECT-TYPE
       SYNTAX OCTET STRING
       ACCESS read-only
       STATUS deprecated
       DESCRIPTION  "See groupLEDInfo"
       ::= { groupInfo 1 }

   groupInfoTable OBJECT-TYPE
       SYNTAX    SEQUENCE OF GroupInfoEntry
       ACCESS    not-accessible
       STATUS    mandatory
       DESCRIPTION  "Table of group specific information."
       ::= { groupInfo 2 }

   groupInfoEntry OBJECT-TYPE
       SYNTAX    GroupInfoEntry
       ACCESS    not-accessible
       STATUS    mandatory
       DESCRIPTION
           "An entry in the table, containing information
        about a single group of ports."
       INDEX    { groupInfoIndex }
       ::= { groupInfoTable 1 }

   GroupInfoEntry ::=
       SEQUENCE {
       groupInfoIndex
           INTEGER,
       groupLEDInfo
           OCTET STRING,
       groupSegmentation
           INTEGER,
       groupSecurity
           INTEGER,
       groupIntruderProtection
           INTEGER,
       groupSrcAddrLearningMode
           INTEGER,
       groupIntruderTrap
           INTEGER,
       groupIntruderDisable
           INTEGER,
       groupOperStatus
           INTEGER,
       groupDescr
           DisplayString,
       groupObjectID
           OBJECT IDENTIFIER,
       groupIPAddress
           IpAddress,
       groupPortCapacity
           INTEGER,
       groupEraseSourceAddressTable
           INTEGER,
       groupAddSourceAddress
           OCTET STRING,
       groupDeleteSourceAddress
           OCTET STRING,
       groupLimitAddressPerPort
           INTEGER,
       groupCheckPrimaryTimer
           INTEGER,
       groupReceiveFailureTimer
           INTEGER,
       groupCheckResampleTimer
           INTEGER
       }

   groupInfoIndex OBJECT-TYPE
       SYNTAX    INTEGER (1..1024)
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "This object identifies the group within the
        repeater for which this entry contains information."
       ::= { groupInfoEntry 1 }

   groupLEDInfo  OBJECT-TYPE
       SYNTAX OCTET STRING
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This information encodes the current state of the module
        per-port LEDs."
       ::= { groupInfoEntry 2 }

   groupSegmentation OBJECT-TYPE
       SYNTAX   INTEGER {
             segmented(1),
             connected(2),
             external(3)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
        "AT-3100 product family only.
         This object controls the segmentation option for this group.
         It may be segmented, connected, or using the module's
         external segmentation switch."
       ::= { groupInfoEntry 3 }

   groupSecurity OBJECT-TYPE
       SYNTAX   INTEGER {
             enabled(1),
             disabled(2),
             external(3)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "AT-3100 product family only.
        This object controls the Security option for this group.
        It may be enabled, disabled, or using module's external
        security switch."
       ::= { groupInfoEntry 4 }


   groupIntruderProtection OBJECT-TYPE
       SYNTAX   INTEGER {
             enabled(1),
             disabled(2)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "AT-3100 and TurboStack product families only.
        This object controls the Intruder Protection option for this
        group/module.  For TurboStack products, disabled turns off
        Intruder Protection and places the module into source address
        Learning Mode.  Enabled turns on Intruder Protection and places
        the module into Secure Mode."
       ::= { groupInfoEntry 5 }



   groupSrcAddrLearningMode OBJECT-TYPE
       SYNTAX   INTEGER {
             mode1(1),
             mode2(2),
             mode3(3),
             mode4(4)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
          "AT-3100 product family only.
           This object indicates the Source Address Learning Mode.
           Mode1 : Automatic; passive devices:  Automatic MAC address
               learning.  Re-learn port MAC address after a port is
               disabled/re-enabled.  Passive devices connected to a
               port will see all backbone traffic.
           Mode2 : Automatic; passive devices:  Automatic MAC address
               learning.  Re-learn port MAC address after link test
               fails (cable removed).  Passive devices connected to a
               port will see all backbone traffic.
           Mode3 : Manual:  No automatic MAC address learning (disabled).
           Mode4 : Automatic; active devices:  Automatic MAC address
               learning.  Re-learn port MAC address after a port is
               disabled/re-enabled.  Passive devices connected to a
               port will see no backbone traffic."
       ::= { groupInfoEntry 6 }



   groupIntruderTrap OBJECT-TYPE
       SYNTAX   INTEGER {
             enabled(1),
             disabled(2)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "AT-3100 and TurboStack product families only.
        This object controls the action to be taken by this group/module
        when an Intruder Alert event occurs.  When this option is
        enabled, the detection of an intruder (a received packet with
        an unlearned or undefined source address) causes a Trap to be
        sent to the configured host manager.  When this option is
        disabled then no Trap is sent on an Intruder Alert event."
       ::= { groupInfoEntry 7 }

   groupIntruderDisable OBJECT-TYPE
       SYNTAX   INTEGER {
             enabled(1),
             disabled(2)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "AT-3100 and TurboStack product families only.
        This object controls the action to be taken by this group/module
        when an Intruder Alert event occurs.  When this option is
        enabled, the detection of an intruder (a received packet with
        an unlearned or undefined source address) causes the port where
        the intruder was detected to be automatically disabled.  When
        this option is disabled then the port will not be disabled on
        an Intruder Alert event."
       ::= { groupInfoEntry 8 }



   groupOperStatus OBJECT-TYPE
       SYNTAX    INTEGER {
             operational(2),
             malfunctioning(3),
             notPresent(4)
         }
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        An object that indicates the operational status of the module.
        For modules that are repeaters, this value is identical to
        the rptrGroupOperStatus object.
        A status of operational(2) indicates that the
        module is present and functional within the chassis.
        A status of malfunctioning(3) indicates that the
        module is present within the chassis but is not functional.
        A status of notPresent(4) indicates that the module is
        temporarily or permanently physically and/or logically
        not a part of the chassis."
       ::= { groupInfoEntry 9 }

   groupDescr OBJECT-TYPE
       SYNTAX    DisplayString (SIZE (0..255))
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        A textual description of the module.
        For modules that are repeaters, this value is identical to
        the rptrGroupDescr object."
       ::= { groupInfoEntry 10 }

   groupObjectID OBJECT-TYPE
       SYNTAX    OBJECT IDENTIFIER
       ACCESS    read-only
       STATUS    deprecated
       DESCRIPTION
           "TurboStack product family only.
        The sysObject identification of the module.
        For modules that are repeaters, this value is identical to
        the rptrGroupObjectID object."
       ::= { groupInfoEntry 11 }

   groupIPAddress OBJECT-TYPE
       SYNTAX    IpAddress
       ACCESS    read-only
       STATUS    deprecated
       DESCRIPTION
           "TurboStack product family only.
        The IP address (if any) of the module.
        For modules that are repeaters, this value is identical to
        the actualIPAddr object.  For non-repeater modules, this
        object identifies the IP address that may be used to
        communicate directly with the module."
       ::= { groupInfoEntry 12 }

   groupPortCapacity OBJECT-TYPE
       SYNTAX    INTEGER (1..1024)
       ACCESS    read-only
       STATUS    deprecated
       DESCRIPTION
           "TurboStack product family only.
        The number of ports contained within the module.  Valid range
        range is 1-1024.  Within each module, the ports are uniquely
        numbered in the range from 1 to groupPortCapacity.
        For modules that are repeaters, this value is identical to
        the rptrGroupPortCapacity object."
       ::= { groupInfoEntry 13 }

   groupEraseSourceAddressTable OBJECT-TYPE
       SYNTAX   INTEGER {
             noerase(1),
             erase(2)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object, when Set to the erase value, will clear (empty)
        the module Source Address Table, deleting all learned MAC
        addresses;  this object will then automatically revert back to
        the noerase state.  When Set to noerase, no action is taken and
        the Source Address Table remains unmodified.  A Get of this
        object will always return the noerase value."
       ::= { groupInfoEntry 14 }

   groupAddSourceAddress OBJECT-TYPE
       SYNTAX    OCTET STRING (SIZE(6))
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object, when Set with a 48-bit MAC address value, will
        add the new MAC address to the module Source Address Table.
        A Get of this object will return a string of length zero."
       ::= { groupInfoEntry 15 }

   groupDeleteSourceAddress OBJECT-TYPE
       SYNTAX    OCTET STRING (SIZE(6))
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object, when Set with a 48-bit MAC address value, will
        delete the MAC address from the module Source Address Table.
        A Get of this object will return a string of length zero."
       ::= { groupInfoEntry 16 }

   groupLimitAddressPerPort OBJECT-TYPE
       SYNTAX   INTEGER {
             noLimit(1),
             limit1Address(2)
        }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object configures the module to allow no limitation
        on number of source addresses on its ports, or limit to
        only 1 source address per port."
       ::= { groupInfoEntry 17 }

  groupCheckPrimaryTimer  OBJECT-TYPE
    SYNTAX   INTEGER (0..65535)
    ACCESS   read-write
    STATUS   mandatory
    DESCRIPTION
        "
         TurboStack product family only.
         The Check Primary Timer is the timer value in seconds 
         which determines how long to wait before checking if
         the primary port could receive again. This timer applies
         when the secondary port is enabled, and the primary port's
         failure is NOT due to loss of link.
         Range: 1 - 65535 in seconds, 0 means don't check receives.
         Default is 60 seconds.
        "
     ::= { groupInfoEntry 18 }

  groupReceiveFailureTimer  OBJECT-TYPE
    SYNTAX   INTEGER (0..65535)
    ACCESS   read-write
    STATUS   mandatory
    DESCRIPTION
        "
         TurboStack product family only.
         The Receive Failure Timer is the timer value in seconds
         which determines how long to wait before the secondary port
         takes over when the primary port is not receiving data.
         This timer applies only when the primary port's failure
         is NOT due to loss of link.
         Range: 0 - 65535 in seconds, 0 means don't check receives.
         Default is 60 seconds.
        "
     ::= { groupInfoEntry 19 }

  groupCheckResampleTimer  OBJECT-TYPE
    SYNTAX   INTEGER (100..65535)
    ACCESS   read-write
    STATUS   mandatory
    DESCRIPTION
        "
         TurboStack product family only.
         The Resample Timer is the timer value in milliseconds
         which determines how long to sample/test if the primary
         port could receive data or is no longer partitioned.
         This timer begins once groupCheckPrimaryTimer has expired,
         and during this sampling time, the secondary port cannot
         repeat data.
         Range: 100 - 65535 milliseconds. Default is 200 milliseconds.
        "
     ::= { groupInfoEntry 20 }


--
-- Following are statistics collected for each module/group in the repeater.
--

   groupStatTable OBJECT-TYPE
       SYNTAX    SEQUENCE OF GroupStatEntry
       ACCESS    not-accessible
       STATUS    mandatory
       DESCRIPTION
           "Table of performance and error statistics for the groups."
       ::= { groupStat 1 }

   groupStatEntry OBJECT-TYPE
       SYNTAX    GroupStatEntry
       ACCESS    not-accessible
       STATUS    mandatory
       DESCRIPTION
           "An entry in the table, containing total
        performance and error statistics for a single
        group.  Regular retrieval of the information in
        this table provides a means of tracking the
        performance and health of the networked devices
        attached to this group's ports.

        The counters in this table are redundant in the
        sense that they are the summations of information
        already available through other objects.  However,
        these sums provide a considerable optimization of
        network management traffic over the otherwise
        necessary retrieval of the individual counters
        included in each sum."
       INDEX    { groupStatIndex }
       ::= { groupStatTable 1 }

   GroupStatEntry ::=
       SEQUENCE {
       groupStatIndex
           INTEGER,
       groupFCSError
           Counter,
       groupAlignError
           Counter,
       groupFrameTooLong
           Counter,
       groupShortEvent
           Counter,
       groupRunt
           Counter,
       groupPortCollision
           Counter,
       groupLateEvent
           Counter,
       groupVeryLongEvent
           Counter,
       groupDataRateMism
           Counter,
       groupAutoPartition
           Counter
,
       groupFrames-64-127bytes
           Counter,
       groupFrames-128-255bytes
           Counter,
       groupFrames-256-511bytes
           Counter,
       groupFrames-512-1023bytes
           Counter,
       groupFrames-1024-1518bytes
           Counter
       }

   groupStatIndex OBJECT-TYPE
       SYNTAX    INTEGER (1..1024)
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "This object identifies the group within the
        repeater for which this entry contains information."
       ::= { groupStatEntry 1 }

  groupFCSError  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the FCS (CRC) Error Counters of all
             ports on this module/group"
      ::= { groupStatEntry 2 }

  groupAlignError  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Alignment Error Counters of all
             ports on this module/group"
      ::= { groupStatEntry 3 }

  groupFrameTooLong  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Frame Too Long Error Counters of all
             ports on this module/group"
      ::= { groupStatEntry 4 }

  groupShortEvent  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Short Event Error Counters of all
             ports on this module/group"
      ::= { groupStatEntry 5 }

  groupRunt  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Runt Error Counters of all
             ports on this module/group"
      ::= { groupStatEntry 6 }

  groupPortCollision  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Port Collision Counters
             of all ports on this module/group"
      ::= { groupStatEntry 7 }

  groupLateEvent  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Late Event Error Counters of all
             ports on this module/group"
      ::= { groupStatEntry 8 }

  groupVeryLongEvent  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Very Long Event Error (Jabber)
             Counters of all ports on this module/group"
      ::= { groupStatEntry 9 }

  groupDataRateMism  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Data Rate Mismatch Error Counters
             of all ports on this module/group"
      ::= { groupStatEntry 10 }

  groupAutoPartition  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION  "The sum total of the Auto Port Partition Counters
             of all ports on this module/group"
      ::= { groupStatEntry 11 }


  groupFrames-64-127bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on this module/group, where
        the frame length was in the range 64 through 127 octets."
      ::= { groupStatEntry 12}

  groupFrames-128-255bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on this module/group, where
        the frame length was in the range 128 through 255 octets."
      ::= { groupStatEntry 13 }

  groupFrames-256-511bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on this module/group, where
        the frame length was in the range 256 through 511 octets."
      ::= { groupStatEntry 14 }

  groupFrames-512-1023bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on this module/group, where
        the frame length was in the range 512 through 1023 octets."
      ::= { groupStatEntry 15 }

  groupFrames-1024-1518bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The sum total number of readable frames received
        on all ports on this module/group, where
        the frame length was in the range 1024 through 1518 octets."
      ::= { groupStatEntry 16 }



--
-- TurboStack product family only:
-- Following is the Source Address Table for each module/group in the repeater.
--

   groupSourceAddressTable  OBJECT-TYPE
       SYNTAX  SEQUENCE OF GroupSATEntry
       ACCESS  not-accessible
       STATUS  mandatory
       DESCRIPTION
           "TurboStack product family only.
        Table of learned and/or configured source MAC addresses which
        defines the only valid and allowable source addresses for
        this module (if Intruder Protection is enabled)."
       ::= { groupSAT 1 }

   groupSATEntry  OBJECT-TYPE
       SYNTAX  GroupSATEntry
       ACCESS  not-accessible
       STATUS  mandatory
       DESCRIPTION
           "TurboStack product family only.
        An entry in the Source Address Table, containing information
        about a single source MAC address."
       INDEX   { groupSATModule, groupSATIndex }
       ::= { groupSourceAddressTable 1 }

   GroupSATEntry  ::=
      SEQUENCE {
       groupSATModule
           INTEGER,
       groupSATIndex
           INTEGER,
       groupSATMacAddress
           OCTET STRING,
       groupSATPort
           INTEGER
       }

   groupSATModule OBJECT-TYPE
       SYNTAX    INTEGER (1..1024)
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object identifies the group within the
        repeater for which this entry contains information."
       ::= { groupSATEntry 1 }

   groupSATIndex OBJECT-TYPE
       SYNTAX    INTEGER (1..1024)
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object identifies the index within the Source Address
        Table for which this entry contains information."
       ::= { groupSATEntry 2 }

   groupSATMacAddress OBJECT-TYPE
       SYNTAX    OCTET STRING (SIZE(6))
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object is the learned or configured source MAC address.
        If no MAC address has been learned for this table entry (if
        this is beyond the logical end of the table) then a string
        of zero length will be returned."
       ::= { groupSATEntry 3 }

   groupSATPort OBJECT-TYPE
       SYNTAX    INTEGER (0..1024)
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "TurboStack product family only.
        This object is the port number where the source MAC address
        was last detected.  If the MAC address has not been detected
        since the system was last started, then this object will
        be zero."
       ::= { groupSATEntry 4 }


--
--  Following are controls and statistics for each port within the repeater.
--

   atiPortTable  OBJECT-TYPE
       SYNTAX  SEQUENCE OF AtiPortEntry
       ACCESS  not-accessible
       STATUS  mandatory
       DESCRIPTION
           "Table of descriptive and status information about
        the ports."
       ::= { portInfo 1 }

   atiPortEntry  OBJECT-TYPE
       SYNTAX  AtiPortEntry
       ACCESS  not-accessible
       STATUS  mandatory
       DESCRIPTION
           "An entry in the table, containing information
        about a single port."
       INDEX   { atiPortGroupIndex, atiPortIndex }
       ::= { atiPortTable 1 }

   AtiPortEntry  ::=
      SEQUENCE {
       atiPortGroupIndex
           INTEGER,
       atiPortIndex
           INTEGER,
       portName
           DisplayString,
       portState
           INTEGER,
       linkTest
           INTEGER,
       altReconnection
           INTEGER,
       polarityCorrection
           INTEGER,
       partitionedLED
           INTEGER,
       linkTestLED
           INTEGER,
       polarityLED
           INTEGER,
       portMACAddress
           MacAddress,
       portFrames-64-127bytes
           Counter,
       portFrames-128-255bytes
           Counter,
       portFrames-256-511bytes
           Counter,
       portFrames-512-1023bytes
           Counter,
       portFrames-1024-1518bytes
           Counter,
       portRedundantPort
           INTEGER,
       portRedundantPosition
           INTEGER,
       portLearningState
           INTEGER
      }
   atiPortGroupIndex OBJECT-TYPE
       SYNTAX    INTEGER (1..1024)
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "This object identifies the group containing the
        port for which this entry contains information."
       ::= { atiPortEntry 1 }

   atiPortIndex OBJECT-TYPE
       SYNTAX    INTEGER (1..1024)
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "This object identifies the port within the group
        for which this entry contains information.
        This value can never be greater than
        rptrGroupPortCapacity for the associated group."
       ::= { atiPortEntry 2 }

   portName   OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..255))
       ACCESS  read-write
       STATUS  mandatory
       DESCRIPTION  "Port Name"
       ::= { atiPortEntry 3 }

   portState  OBJECT-TYPE
       SYNTAX  INTEGER {
             enabled(1),
             disabled(2),
             enabledByRedund(3),
             disabledByRedund(4)
         }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
          "Port State option:  enabled allow repeating of packets
           through the port;  disabled turns off the port and prevents
           packets repeating through the port."
       ::= { atiPortEntry 4 }

   linkTest  OBJECT-TYPE
       SYNTAX   INTEGER {
             enabled(1),
             disabled(2)
        }
       ACCESS   read-write
       STATUS   mandatory
       DESCRIPTION
          "Link Test option:  enabled turns on checking for link test
           signals for the port;  disabled turns off checking for
           link test signals."
       ::= { atiPortEntry 5 }

   altReconnection  OBJECT-TYPE
       SYNTAX   INTEGER {
             standardIEEE(1),
             alternate(2)
         }
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
          "Reconnection Method: 1=IEEE Standard, 2=Alternate."
       ::= { atiPortEntry 6 }

   polarityCorrection  OBJECT-TYPE
       SYNTAX   INTEGER {
             enabled(1),
             disabled(2)
         }
       ACCESS   read-write
       STATUS   mandatory
       DESCRIPTION
          "Polarity Correction option:  enabled turns on automatic
           polarity correction for the port;  disabled turns off automatic
           polarity correction."
       ::= { atiPortEntry 7 }

   partitionedLED  OBJECT-TYPE
       SYNTAX    INTEGER {
             notpartitioned(1),
             partitioned(2)
         }
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "This object reflects the current actual partitioning state of
        the port.  The notpartitioned value means that the port is
        operational and repeating through the port is enabled.
        The partitioned value means that the port is not operational
        and repeating through the port is disabled."
       ::= { atiPortEntry 8 }

   linkTestLED  OBJECT-TYPE
       SYNTAX    INTEGER {
             nolinktesterror(1),
             linktesterror(2)
         }
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "This object reflects the current actual link test state of
        the port.  The nolinktesterror value means that valid
        link integrity test signals have been detected on the port,
        indicating that an operable device is cabled to the port.
        The linktesterror value means that no link integrity test
        signals have been detected, indicating removal or failure
        of the port-to-device cable, or that the device is not
        operational.  This object applies only to UTP (twisted pair)
        and fiber optic ports (not AUI or BNC ports)."
       ::= { atiPortEntry 9 }

   polarityLED  OBJECT-TYPE
       SYNTAX    INTEGER {
             notreversed(1),
             reversed(2)
         }
       ACCESS    read-only
       STATUS    mandatory
       DESCRIPTION
           "This object reflects the current actual polarity state of
        the port.  The notreversed value means that the port-to-device
        cable connection is properly polarized.  The reversed value
        means that the cable connection has reversed polarity.
        This object applies only to UTP (twisted pair) and
        fiber optic ports (not AUI or BNC ports)."
       ::= { atiPortEntry 10 }

   portMACAddress OBJECT-TYPE
       SYNTAX    MacAddress
       ACCESS    read-write
       STATUS    mandatory
       DESCRIPTION
           "AT-3100 product family only.
        This object is either the MAC address of the
        last readable frame (i.e., counted by
        rptrMonitorPortReadableFrames) received by this
        port, or a manually input MAC address. If neither
        of those exists, then a string of length zero is
        returned. If a 'read' operation is performed on
        this object, the value it returns is the same as
        the value returned by object
        'rptrAddrTrackNewLastSrcAddress' in the Standard
        Repeater MIB (RFC1516)."
       ::= { atiPortEntry 11 }


  portFrames-64-127bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The number of readable frames received on this port where
        the frame length was in the range 64 through 127 octets."
       ::= { atiPortEntry 12 }

  portFrames-128-255bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The number of readable frames received on this port where
        the frame length was in the range 128 through 255 octets."
       ::= { atiPortEntry 13 }

  portFrames-256-511bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The number of readable frames received on this port where
        the frame length was in the range 256 through 511 octets."
       ::= { atiPortEntry 14 }

  portFrames-512-1023bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The number of readable frames received on this port where
        the frame length was in the range 512 through 1023 octets."
       ::= { atiPortEntry 15 }

  portFrames-1024-1518bytes  OBJECT-TYPE
       SYNTAX     Counter
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        The number of readable frames received on this port where
        the frame length was in the range 1024 through 1518 octets."
       ::= { atiPortEntry 16 }

  portRedundantPort  OBJECT-TYPE
       SYNTAX     INTEGER
       ACCESS     read-write
       STATUS     mandatory
       DESCRIPTION
           "TurboStack product family only.
        This is the redundant port for atiPortIndex.
        If the port is a secondary port as indicated in
        portRedundantPosition, then it serves as a backup port.
        This would indicate paired ports with redundant link."
       ::= { atiPortEntry 17 }

  portRedundantPosition   OBJECT-TYPE
    SYNTAX   INTEGER {
           primary(1),
           secondary(2),
           notapplicable(3)
         }
    ACCESS   read-only
    STATUS   mandatory
    DESCRIPTION
         "TurboStack product family only.
          This object will retrieve the redundant position of the
          port, primary or secondary port, if the port has a
          redundant link to it."
     ::= { atiPortEntry 18 }

  portLearningState   OBJECT-TYPE
    SYNTAX   INTEGER {
           enabled(1),
           disabled(2)
         }
    ACCESS   read-write
    STATUS   mandatory
    DESCRIPTION
        "
         TurboStack product family only.
         This object enable the learning on a port to be shut ON or OFF.
         Once the learning is Shut Off, the learning of MAC Address 
         will stop.
         "
     ::= { atiPortEntry 19 }
    

--  ATI Enterprise Trap --

-- These are the object I am adding where the Intruder is reported to the
-- Manager when sending a trap.
-- The objects are to track down the MAC address, the module 
-- on which this appeared and the port on which the intruder was seen.


atiTrapIntruderMacAddress OBJECT-TYPE
      SYNTAX    OCTET STRING (SIZE(6))
       ACCESS   not-accessible
       STATUS mandatory
    DESCRIPTION
    " The Mac address of the Intruder which is different from the rfc1516 
     object rptrAddrTrackLastSourceAddress is seen on port which is the 
     the next object"
    ::= { atiTrapAttrs  1 }


atiTrapIntruderModuleNumber OBJECT-TYPE
       SYNTAX   INTEGER 
       ACCESS   not-accessible
       STATUS mandatory
    DESCRIPTION
    " This is the module number on which an intruder was seen."
    ::= { atiTrapAttrs  2 }

atiTrapIntruderPortNumber OBJECT-TYPE
       SYNTAX   INTEGER 
       ACCESS   not-accessible
       STATUS mandatory
    DESCRIPTION
    " This is the port number on which an intruder was seen."
    ::= { atiTrapAttrs  3 }

atiPortChangeDirection OBJECT-TYPE
       SYNTAX    INTEGER {
             primarytosecondary(1),
             secondarytoprimary(2)
         }
       ACCESS   not-accessible
       STATUS mandatory
    DESCRIPTION
    " This is the direction of redundant port change. These two
      values are used in the trap atiRedundantPortChangeTrap.
    "
    ::= { atiTrapAttrs  4 }

   intruderProtectionTrap TRAP-TYPE
       ENTERPRISE  repeater
       VARIABLES   { rptrAddrTrackNewLastSrcAddress }
       DESCRIPTION
           "This trap is replaced by atiIntruderProtectionTrap starting from
        firmware ver 3.0.
        AT-3100 and TurboStack product families only.
        This trap is sent when an Intruder Alert occurs on a port due
        to a received packet with an unauthorized source MAC address.
        Intruder Protection for the module must be enabled.
        The varBind list contains the MAC address of the intruder."
       ::= 20

   atiIntruderProtectionTrap TRAP-TYPE
       ENTERPRISE  repeater
       VARIABLES   { atiTrapIntruderModuleNumber, atiTrapIntruderPortNumber,
             atiTrapIntruderMacAddress  }
       DESCRIPTION
       "AT-3100 and TurboStack product families only.
        This trap is sent when an Intruder Alert occurs on a module/port due
        to a received packet with an unauthorized source MAC address.
        Intruder Protection for the module must be enabled.
        The varBind list contains the module number, port number,
        and the MAC address of the intruder."
       ::= 21

   atiRedundantPortChangeTrap TRAP-TYPE
       ENTERPRISE  repeater
       VARIABLES   { atiPortGroupIndex, atiPortIndex,
             portRedundantPort, atiPortChangeDirection }
       DESCRIPTION
       "TurboStack product family only.
        This trap is sent when ports, which are configured for
        redundant links, change from primary to secondary or
        secondary to primary."
       ::= 22

-- switch mib


   ftConfig        OBJECT-TYPE
                      SYNTAX SEQUENCE OF FtConfig
                      ACCESS not-accessible
                      STATUS mandatory
                      DESCRIPTION "Bridge FT operational parameters"
                      ::= { filterTable 1 }

   FtConfig   ::= SEQUENCE {
                        ftMaxAge
                           INTEGER,
                        ftMaxRemove
                           INTEGER,
                        ftMaxFilter
                           INTEGER,
                        ftAgeTime
                           INTEGER,
                        ftMaxPerm
                           INTEGER,
                        ftForwMBcast
                           INTEGER,
                        ftSecureMode
                           INTEGER
                }

  ftMaxAge   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Seconds before an unreferenced dynamic FT
             entry is removed"
                ::= { ftConfig 1}
  ftMaxRemove   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Max number table entries removed each
                time table overflows"
                ::= { ftConfig 2}
  ftMaxFilter   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Max number FT entries"
                ::= { ftConfig 3}
  ftAgeTime   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Seconds between FT table entries"
                ::= { ftConfig 4}
  ftMaxPerm   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Max number of permanent FT entries. May be set
                 to zero which causes all non-system FT entries 
                 to be deleted"
                ::= { ftConfig 5}
  ftForwMBcast  OBJECT-TYPE
                SYNTAX  INTEGER {
                forwardmulticast (1),
                filtermulticast (0)
        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Flag indicates if multicast (including broadcast)
                 packets are to be forwarded (1) or discarded (0)"
                ::= { ftConfig 6}
  ftSecureMode   OBJECT-TYPE
                SYNTAX  INTEGER {
                 staticaddr(1),
                 dynamicaddr(0)
        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Flag indicates if bridge will learn addresses"
                ::= { ftConfig 7}

   FdbConfig   ::= SEQUENCE {
                        ftMaxFilter
                           INTEGER,
                        ftMaxPerm
                           INTEGER,
                        ftForwMBcast
                           INTEGER,
                        ftSecureMode
                           INTEGER
                }

  ftEntry    OBJECT-TYPE
                SYNTAX SEQUENCE OF FtEntry
                ACCESS not-accessible
                STATUS mandatory
                DESCRIPTION "Bridge FT entries each selected by destination 
                address"    
        INDEX { ftAddr } -- dummy index
                ::= {  filterTable 2}

  FtEntry    ::=
                SEQUENCE {
             ftAddr
            OCTET STRING,
                     ftAge
                        INTEGER,
                     ftDisp
                        INTEGER
                }
  ftAddr   OBJECT-TYPE
                SYNTAX  OCTET STRING (SIZE (6))
                ACCESS  not-accessible
                STATUS  mandatory
                DESCRIPTION "destination address (dummy index)"
                ::= { ftEntry 91 }

  ftAge   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "FT entry age since last referenced in seconds"
                ::= { ftEntry 1 }

  ftDisp  OBJECT-TYPE
                SYNTAX  INTEGER {
                    dynamicForwardP1 (4),
                    dynamicForwardP2 (8),
                    dynamicFlood     (16),
                    dynamicDiscard   (32),
                    staticForwardP1  (5),
                    staticForwardP2  (9),
                    staticFlood      (17),
                    staticDiscard    (33),
                    sysSendup        (67),
                    sysDiscard       (35),
                    sysFlood         (83)
                }
                ACCESS read-write
                STATUS mandatory
                DESCRIPTION "FT entry disposition. Can be more than one OR'ed together"
                ::= { ftEntry 2 }

   interfaceErrors  OBJECT-TYPE
                SYNTAX InterfaceErrors
                ACCESS not-accessible
                STATUS mandatory
                DESCRIPTION "Set of Ethernet link level errors"
        INDEX { ifePort }  -- dummy index
        ::= {alliedTelesyn 3}

   InterfaceErrors ::=
                SEQUENCE {
            ifePort    
               INTEGER,
                        ifeInBusErr
                           Counter,
                        ifeInShortPkt
                           Counter,
                        ifeInAlgError
                           Counter,
                        ifeInBadSize
                           Counter,
                        ifeInOverflow
                           Counter,
                        ifeInCRCErr
                           Counter,
                        ifeOutColl16
                           Counter,
                        ifeOutCol
                           Counter,
                        ifeOutShortPkt
                           Counter,
                        ifeOutUnderflow
                           Counter,
                        ifeOutBusErr
                           Counter
                }

-- dummy index
  ifePort   OBJECT-TYPE
                SYNTAX  INTEGER {
            Port1 (1),
            Port2 (2)
        }
                ACCESS  not-accessible
                STATUS  mandatory
                ::= { interfaceErrors 91 }

  ifeInBusErr   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of EtherStar read bus errors that
                 have occurred"
                ::= { interfaceErrors 1 }
  ifeInShortPkt   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of short packets received"
                ::= { interfaceErrors 2 }
  ifeInAlgError   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of packets received with alignment errors"
                ::= { interfaceErrors 3 }
  ifeInBadSize   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of packets received greater than 1518 bytes"
                ::= { interfaceErrors 4 }
  ifeInOverflow   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of times receive buffer overflowed"
                ::= { interfaceErrors 5 }
  ifeInCRCErr   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of CRC errors detected"
                ::= { interfaceErrors 6 }
  ifeOutColl16   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of packets discarded due to excessive
                 collisions"
                ::= { interfaceErrors 7 }
  ifeOutCol   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of collisions detected"
                ::= { interfaceErrors 8 }
  ifeOutShortPkt   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of short packets transmitted"
                ::= { interfaceErrors 9 }
  ifeOutUnderflow   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of packets transmitted w/programmed 
                 length > buffered transmitted data"
                ::= { interfaceErrors 10 }
  ifeOutBusErr   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of EtherStar write bus errors"
                ::= { interfaceErrors 11 }


  forwardCounters  OBJECT-TYPE
                SYNTAX ForwardCounters
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION "Counters associated with bridge entity"
        INDEX { fcPort } -- dummy index
        ::= {alliedTelesyn 4}

  ForwardCounters ::=
                SEQUENCE {
            fcPort
               INTEGER,
                        fcInOctets
                           Counter,
                        fcInPkts
                           Counter,
                        fcInNUcastPkts
                           Counter,
                        fcForwOctets
                           Counter,
                        fcForwPkts
                           Counter,
                        fcFiltOctets
                           Counter,
                        fcFiltPkts
                           Counter
                }

-- dummy index
  fcPort   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                ::= { forwardCounters 91 }

  fcInOctets   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number bytes received by bridge entity on 
                 specified port"
                ::= { forwardCounters 1 }
  fcInPkts   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number packets received by bridge entity on
                 specified port"
                ::= { forwardCounters 2 }
  fcInNUcastPkts   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number multicast/broadcast packets received by
                 bridge enity on specified port"
                ::= { forwardCounters 3 }
  fcForwOctets OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number bytes forwarded by bridge entity onto
                 specified port"
                ::= { forwardCounters 4 }
  fcForwPkts   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of packets forwarded by bridge enity 
                onto specified port"
                ::= { forwardCounters 5 }
  fcFiltOctets   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of bytes received on specified port
                 that were discarded by bridge enity"
                ::= { forwardCounters 6 }
  fcFiltPkts   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of packets dicarded by filtering by
                 bridge enity"
                ::= { forwardCounters 7 }

  systemCounters  OBJECT-TYPE
                SYNTAX SystemCounters
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION "System operating s/w counters"
        ::= {alliedTelesyn 5}

  SystemCounters ::=
                SEQUENCE {
                        sysMemFree
                           Counter,
                        sysMemAllocFail
                           Counter,
                        sysMemTotAllocFail
                           Counter,
                        sysMemAllocTooBig
                           Counter,
                        sysMemFreeFail
                           Counter,
                        sysTimeToReset
                           Counter,
                        sysPanicMesg
                           OCTET STRING,
                        sysResetCount
                           Counter
                }


  sysMemFree   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of buffers of a particular size on 
                the memory free list"
                ::= { systemCounters 1 }
  sysMemAllocFail  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of allocation failures for a particular 
                buffer size"
                ::= { systemCounters 2 }
  sysMemTotAllocFail   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Total number of memory allocation failures"
                ::= { systemCounters 3 }
  sysMemAllocTooBig  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of memory allocation requests that failed"
                ::= { systemCounters 4 }
  sysMemFreeFail   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of memory free requests that failed"
                ::= { systemCounters 5 }
  sysTimeToReset   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Number of seconds unit bridge reset"
                ::= { systemCounters 6 }
  sysPanicMesg   OBJECT-TYPE
                SYNTAX  OCTET STRING
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Error message associated with last s/w 
                generated reset"
                ::= { systemCounters 7 }
  sysResetCount   OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of times bridge has been reset other
                 than power on/off"
                ::= { systemCounters 8 }


  stBridge  OBJECT-TYPE
                SYNTAX SEQUENCE OF StBridge
                ACCESS not-accessible
                STATUS mandatory
                DESCRIPTION "Bridge specific parameters related to 
                operation of Spanning Tree Protocol"
                ::= { spanningTree 1 }

  StBridge ::=
                SEQUENCE {
                        stBrName
                           DisplayString,
                        stBrIdent
                           OCTET STRING,
                        stBrMaxAge
                           INTEGER,
                        stBrHelloTime
                           INTEGER,
                        stBrForwDelay
                           INTEGER,
                        stBrIsRoot
                           INTEGER,
                        stBrIsDesig
                           INTEGER,
                        stBrSpanAddr
                           OCTET STRING,
                        stBrPriority
                           INTEGER,
                        stBrSTPDisabled
                           INTEGER
                }


  stBrName   OBJECT-TYPE
                SYNTAX  DisplayString
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Comment string denoting the bridge"
                ::= { stBridge 1 }
  stBrIdent   OBJECT-TYPE
                SYNTAX  OCTET STRING
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "802.1 Bridge ID"
                ::= { stBridge 2 }
  stBrMaxAge   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "802.1 Max BPDU Age (sec) for bridge"
                ::= { stBridge 3 }
  stBrHelloTime   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "802.1 Hello Time (sec) for bridge"
                ::= { stBridge 4 }
  stBrForwDelay   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "802.1 Forward Delay Time (sec) for bridge"
                ::= { stBridge 5 }
  stBrIsRoot   OBJECT-TYPE
                SYNTAX  INTEGER {
                  isroot(1),
                  notroot(0)
        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Bridge is root (1=yes 0=no)"
                ::= { stBridge 6 }
  stBrIsDesig   OBJECT-TYPE
                SYNTAX  INTEGER {
                  isdesigbridge(1),
                  notdesigbridge(0)
        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Flag indicating status of bridge as designated 
                bridge (1=yes 0=no)"
                ::= { stBridge 7 }
  stBrSpanAddr   OBJECT-TYPE
                SYNTAX  OCTET STRING
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "MAC address used as Spanning Tree Protocol 
                multicast address"
                ::= { stBridge 8 }
  stBrPriority   OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "802.1 bridge priority"
                ::= { stBridge 9 }
  stBrSTPDisabled   OBJECT-TYPE
                SYNTAX  INTEGER {
                   stpdisabled(1),
                   stpenable(0)
        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "Variable to enable/disable operation of Spanning
                 Tree (1=STP on 0=STP off)"
                ::= { stBridge 10 }

  stRoot   OBJECT-TYPE
                SYNTAX SEQUENCE OF StRoot
                ACCESS not-accessible
                STATUS mandatory
                DESCRIPTION "Parameters related to operation of Spanning
                 Tree Protocol for Root bridge"
                ::= { spanningTree 2 }

  StRoot ::=
                SEQUENCE {
                        stRtIdent
                           OCTET STRING,
                        stRtCost
                           INTEGER,
                        stRtPort
                           INTEGER,
                        stRtMaxAge
                           INTEGER,
                        stRtHelloTime
                           INTEGER,
                        stRtForwDelay
                           INTEGER
                }

  stRtIdent  OBJECT-TYPE
                SYNTAX  OCTET STRING
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "802.1 Bridge ID of current Root bridge"
                ::= { stRoot 1 }
  stRtCost  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "802.1 Root Path Cost of current Root bridge"
                ::= { stRoot 2 }
  stRtPort  OBJECT-TYPE
                SYNTAX  INTEGER {
            RootPort1(1),
            RoorPort2(2)
        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Port number of port that provides path to
                 current Root bridge"
                ::= { stRoot 3 }
  stRtMaxAge  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "802.1 Max BPDU Age specified by current known Root bridge"
                ::= { stRoot 4 }
  stRtHelloTime  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "802.1 Hello Time specified by current Root bridge"
                ::= { stRoot 5 }
  stRtForwDelay  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "802.1 Forward Delay specified by current Root
                 bridge"
                ::= { stRoot 6 }




  stPort   OBJECT-TYPE
                SYNTAX SEQUENCE OF StPort
                ACCESS not-accessible
                STATUS mandatory
                DESCRIPTION "Port specific parameters related to operation of
                Spanning Tree Protocol"
        INDEX { stPrtPort } -- dummy indeex
                ::= { spanningTree 3 }

  StPort ::=
                SEQUENCE {
            stPrtPort
               INTEGER,
                        stPrtState
                           INTEGER,
                        stPrtCost
                           INTEGER,
                        stPrtIsDesig
                           INTEGER,
                        stPrtIsRoot
                           INTEGER,
                        stPrtDesigRoot
                           OCTET STRING,
                        stPrtDesigCost
                           INTEGER,
                        stPrtDesigBridge
                           OCTET STRING,
                        stPrtDesigPort
                           INTEGER,
                        stPrtPriority
                           INTEGER
                }

-- dummy index
  stPrtPort OBJECT-TYPE
        SYNTAX INTEGER {
            Port1(1),
            Port2(2)
        }
        ACCESS not-accessible
        STATUS mandatory
                ::= { stPort 91 }

  stPrtState  OBJECT-TYPE
                SYNTAX  INTEGER {
                  disabled(0),
                  blocked(1),
                  listen(2),
                  learn(4),
                  forward(8)

        }
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "802.1 Port State disable and blocked states"
                ::= { stPort 1 }

  stPrtCost  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "802.1 Port Path Cost"
                ::= { stPort 2 }
  stPrtIsDesig  OBJECT-TYPE
                SYNTAX  INTEGER {
            isDesig(1),
            notDesig(0)
        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Status of port as designated port for LAN"
                ::= { stPort 3 }
  stPrtIsRoot  OBJECT-TYPE
                SYNTAX  INTEGER {
            isRoot(1),
            notRoot(0)
        }
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Status of port as Root Port"
                ::= { stPort 4 }
  stPrtDesigRoot  OBJECT-TYPE
                SYNTAX  OCTET STRING
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Bridge ID of Root brigde"
                ::= { stPort 5 }
  stPrtDesigCost  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Path Cost to Root bridge as advertised by the designated bridge"
                ::= { stPort 6 }
  stPrtDesigBridge  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Bridge ID of designated bridge"
                 ::={ stPort 7}
  stPrtDesigPort  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Port ID of designated port"
                ::= { stPort 8 }

  stPrtPriority  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  read-write
                STATUS  mandatory
                DESCRIPTION "802.1 Port Priority"
                ::= { stPort 9 }


  spanTreeStats   OBJECT-TYPE
                SYNTAX SEQUENCE OF SpanTreeStats
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION "Spanning Tree stats on counters"
        INDEX { stsPort } -- dummy index
                ::= { spanningTree 4 }

  SpanTreeStats  ::=
                SEQUENCE {
            stsPort
               INTEGER,
                        stsPortDisable
                           Counter,
                        stsPortEnable
                           Counter,
                        stsInBadLen
                           Counter,
                        stsInUnknown
                           Counter,
                        stsIn8021Man
                           Counter,
                        stsInConfig
                           Counter,
                        stsOutConfig
                           Counter,
                        stsOutTopoChg
                           Counter
                }

-- dummy index
  stsPort  OBJECT-TYPE
                SYNTAX  INTEGER
                ACCESS  not-accessible
                STATUS  mandatory
                ::= { spanTreeStats 91 }

  stsTopoChanges  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of topology changes that have occured
                 since power-on"
                ::= { spanTreeStats 1 }

  stsConfigTimeout  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of timeouts due to config BPDU not received"
                ::= { spanTreeStats 2 }
  stsPortDisable  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of times port has been disabled since
                 power-on"
                ::= { spanTreeStats 3 }
  stsPortEnable  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of times port has been enabled since 
                power-on"
                ::= { spanTreeStats 4 }
  stsInBadLen  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of STP frames received with bad lenth
                 by this port"
                ::= { spanTreeStats 5 }
  stsInUnknown  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Packets received with bad 802.3 LSAP number by
                 this port"
                ::= { spanTreeStats 6 }
  stsIn8021Man  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Packets received with 802.1 Management LSAP
                 (discarded)"
                ::= { spanTreeStats 7 }
  stsInConfig  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of config BPDUs received by this port"
                ::= { spanTreeStats 8 }
  stsOutConfig  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of config BPDUs transmitted by this port"
                ::= { spanTreeStats 9 }
  stsOutTopoChg  OBJECT-TYPE
                SYNTAX  Counter
                ACCESS  read-only
                STATUS  mandatory
                DESCRIPTION "Number of Topology Change Notification BPDU
                 transmitted by this port"
                ::= { spanTreeStats 10 }

  StpGenStats ::= SEQUENCE {
        stsTopoChanges     Counter,
        stsConfigTimeout     Counter
    }

    --
    -- Filter range table
    --
    filterRange OBJECT IDENTIFIER ::= { alliedTelesyn 7 }

    --
    -- The maximum number of filter range table entries when read
    -- (GET). Set to zero to delete all filter range table entries.
    -- A set with any other value is ignored.
    --
    frNumRange OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION "The maximum number of filter range table entries when
             read (GET). Set to zero to delete all filter range 
             table entries. A set with any other value is ignored."
        ::=  { filterRange 1 }

    --
    -- Filter range table entry. Instance is the range table number
    -- (1 to crFr_NumRange). Each entry has the following format:
    --
    --    uchar   fr_LowDest[6];    /* low bound of destination */
    --    uchar   fr_LowSrc[6];    /* low bound of source */
    --    ushort    fr_LowType;    /* low bound of type */
    --    uchar   fr_HighDest[6];    /* high bound of destination */
    --    uchar    fr_HighSrc[6];    /* high bound of source */
    --    ushort    fr_HighType;    /* high bound of type */
    --    uchar     fr_flag;    /* disposition flag */
    --    unchar    fr_fill;        /* round up size */
    --
    -- The LowType and  HighType are in network byte order
    -- (motorola 68K). The flag is one of the bridge filter
    -- table disposition values.
    --
    frEntry OBJECT-TYPE
        SYNTAX  SEQUENCE OF OCTET STRING
        ACCESS  read-write
        STATUS  mandatory
        INDEX { frIndex }
        ::=  { filterRange 2 }

    frIndex OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  not-accessible
        STATUS  mandatory
        ::=  { filterRange 91 }

    filterRangeEntry ::= SEQUENCE {
        frIndex        INTEGER,
        frEntry        OCTET STRING
    }

END