#1617 IP address in ipAddrTable may have wrong length

64-bit
closed
nobody
agent (1105)
5
2012-11-08
2006-06-11
No

When SNMP-agent built for 64-bit arch, it reply PDUs
for IP-MIB::ipAddrEndty.ipAdEntAddr with OCTET STRING
length equal to 8 instead of correct 4.

In details, it is caused by assignment:

*var_len = sizeof(long_return);

in function 'var_ipAddrEntry()' in module
mibgroup/mibII/ipAddr.c

'long_return' has type 'long' and has size 8.

Discussion

  • Thomas Anders

    Thomas Anders - 2006-06-11

    Logged In: YES
    user_id=848638

    What net-snmp version? Can you reproduce this with 5.3.1.pre3?

     
  • Konstantin Abramenko

    Logged In: YES
    user_id=1149016

    I see it with 5.3.0.1.
    I'm sorry, there is respecive fix in current CVS.
    this bug seems out of date.

     