Hi IPMITOOL Team,

This is regarding ipmitool sdr and ipmitool sensor o/p.
ipmitool has an issue where it prints the sensor reading incorrectly for discrete and threshold type sensors.
IPMI specification’s Get Sensor Reading command says that Get Sensor Reading response byte 2 has the sensor reading, but only for sensors returning an analog reading. Ipmitool is returning this byte as a reading for discrete and threshold sensors as well.
We have identified bux in sensor and sdr command response data parsing.

Please find the attached patch and o/p after fix and before fix.
Spec for get sensor reading.

Br,
MSR

1 Attachments

Discussion

  • mareedu srinivasa rao

    sensor and sdr o/p

     
  • mareedu srinivasa rao

    get sensor reading snap shot from ipmi spec

     
  • mareedu srinivasa rao

    Hi Z,

    Can i get update on this.

    Br,