#5 Protocol error

closed-fixed
nobody
None
5
2008-07-08
2008-02-22
OK1RR
No

All applications using hamlib (xlog, cqrlog, tlf tested) returning the same error message:
Error my_get_mode: 5
Error my_get_freq: 8

This is indicated as protocol error. The error message appears any time if the radio is polled. Otherwise, the radio control works.

73,
Martin, OK1RR
martin@ok1rr.com

Discussion

  • Joop Stakenborg

    Joop Stakenborg - 2008-02-24

    Logged In: YES
    user_id=26744
    Originator: NO

    Martin, please contact the hamlib-developer mailing list with some more datails, e.g. which rig where you using.

     
  • Nate Bargmann

    Nate Bargmann - 2008-07-08

    Logged In: YES
    user_id=129349
    Originator: NO

    Is this still an issue? Does the issue still exist when using the latest CVS snapshot from http://hamlib.sourceforge.net/bleeding-edge/ What radio backend do you use?

    If there is no response in 30 days or so, I'll close this bug.

     
  • OK1RR

    OK1RR - 2008-07-08

    Logged In: YES
    user_id=1917693
    Originator: YES

    This bug seems solved (in hamlib-1.2.8cvs-20080621.tar.gz and above). It was a long-time bug observed with Kenwood TS-950SD and also Ten-Tec Orion. Now the cvs hamlib works fine with my Orion (on Slackware 12.1). Many thanks should go also to Martin, AA6E, who solved another bug in the Orion backend (radio # 1608.

    73,
    Martin, OK1RR

     
  • Nate Bargmann

    Nate Bargmann - 2008-07-08
    • status: open --> closed-fixed
     
  • Nate Bargmann

    Nate Bargmann - 2008-07-08

    Logged In: YES
    user_id=129349
    Originator: NO

    Thanks, Martin.

    I am closing this report.

    73, de Nate >>

     