When in the Component Creator, for heat capacity, when changing the unit system, from SI to English, for example, when changing the unit system back to SI, Temperature units are changing from ºF to K, but Cp units are not changing

Discussion

  • Daniel Medeiros

    Daniel Medeiros - 2015-10-21
    • status: open --> accepted
    • assigned_to: Gregor Reichert
    • Version: 3.4 --> 3.5
     
  • Gregor Reichert

    Gregor Reichert - 2015-10-27

    Hi Elffuhs,
    i checked this but i can't find an error. This is the intended behaviour!

    The units in the headings of experimental data are set to the selected units upon changing the unit system right now. The same is the case for labeling of the diagram axis.
    You probably mean the text below the parameter input fields marked with a " * ". This label is kept always at the same unit as this is the internal standard unit which is used inside the database. The user has to transform the parameters by himself into this unit in case he wants to deliver the parameters directely instead of doing a regression. If a regression is done, DWSIM is transforming the experimental data into this unit system prior to running the regression.

    If you still think there is a problem please let me know. Otherwise I will close this case within the next days.

    Regards
    Gregor

     
  • Gregor Reichert

    Gregor Reichert - 2015-11-05
    • status: accepted --> closed