Migrate from GitHub to SourceForge with this tool. Check out all of SourceForge's recent improvements.
Close

#58 CORE should put dampers into safe position on shutdown

Annoyance
closed-fixed
CORE (13)
5
2005-04-21
2004-03-15
No

Currently, the dampers are left wherever they are.
Instead, when CORE is shutting down, they have to be
put in a position that is defined as "safe" in
configuration.

The reason these values are desirable to have in the
configuration is that with DZ inactive, a house may be
somewhat balanced if the dampers are in certain
non-default positions.

Discussion

  • Vadim Tkachenko

    Vadim Tkachenko - 2004-03-15

    Logged In: YES
    user_id=16279

    Don't forget to either wait until transition is complete, or
    shut off the crawl transformer before issuing the
    positioning command

     
  • Vadim Tkachenko

    Vadim Tkachenko - 2005-04-21
    • status: open --> closed-fixed
     