- labels: --> dxtbx, Format, trusted_range
The images for the xia2_regression mad_example data show a trusted range starting at -39 which seems rather odd - presumably it should not be so:
$ dials.show_models $(libtbx.find_under_build xia2_regression)/test_data/mad_example/12287_1_E1_001.img
The following parameters have been modified:
input {
datablock =
}
Format: <class 'dxtbx.format.formatsmvadscsn445.formatsmvadscsn445'="">
/home/hko55533/software/cctbx/build/xia2_regression/test_data/mad_example/12287_1_E1_###.img
Detector:
Panel:
pixel_size:{0.1024,0.1024}
image_size: {2048,2048}
trusted_range: {-39,65495}
thickness: 0
material:
fast_axis: {1,0,0}
slow_axis: {0,-1,0}
origin: {-105.1,108.95,-170}</class>
Beam:
wavelength: 0.97966
sample to source direction : {0,0,1}
divergence: 0
sigma divergence: 0
polarization normal: {0,1,0}
polarization fraction: 0.999
Scan:
image range: {1,1}
oscillation: {290,1}
Goniometer:
Rotation axis: {1,0,0}
Fixed rotation: {1,0,0,0,1,0,0,0,1}
Setting rotation:{1,0,0,0,1,0,0,0,1}