Cooldt calculate the cooling duration of a multi-layers pipe in a cold environment. The duration to reach the “Final fluid temperature” or cool-down time (CDT) is calculated by solving the heat equation in cylindrical coordinates with a flux conservative formulation.

Features

  • Flux Conservative Formulation of Transient Heat Transfer
  • Automatic meshing and time step calculation (0.1% accuracy)
  • LibreOffice and Excel interfaces
  • Excel Add-in
  • Gnuplot Compatible Output
  • 32 and 64 bits versions

Project Samples

Project Activity

See All Activity >

License

BSD License

Follow Cooldt

Cooldt Web Site

Other Useful Business Software
Enterprise-grade ITSM, for every business Icon
Enterprise-grade ITSM, for every business

Give your IT, operations, and business teams the ability to deliver exceptional services—without the complexity.

Freshservice is an intuitive, AI-powered platform that helps IT, operations, and business teams deliver exceptional service without the usual complexity. Automate repetitive tasks, resolve issues faster, and provide seamless support across the organization. From managing incidents and assets to driving smarter decisions, Freshservice makes it easy to stay efficient and scale with confidence.